Cited by 48Microgrid Control and OptimizationPower System Optimization and StabilityOptimal Power Flow Distribution

Effect of reconfiguration and meshed networks on the small-signal stability margin of droop-based islanded microgrids

Dheer, Dharmendra Kumar, Kulkarni, Onkar Vitthal, Doolla, Suryanarayana, Rathore, Akshay Kumar·2018·IEEE Transactions on Industry Applications

Abstract

This paper studies and analyzes the effect of reconfiguration and network type (mesh/radial) on the small-signal stability margin of a droop-based islanded microgrid. Eigenvalue analysis is performed on three systems: a low-voltage microgrid, the standard IEEE 33-bus islanded system with three and five sources, and the standard IEEE 69-bus islanded system with three sources. From eigenvalue analysis, it is observed that the reconfiguration and network type have notable impact on the small-signal stability margin. The analysis and analytical results are initially verified and confirmed through time-domain simulations using MATLAB/SIMULINK for the system considered. Experimental results are demonstrated on the developed microgrid prototype to support the claims and validate the proposed analysis and results.

Integrity signals

Registry

Crossref · 10.1109/tia.2018.2796590

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Authors
Dheer, D. K., Kulkarni, O. V., Doolla, S., & Rathore, A. K.
Affiliations
  • Concordia University (CA)
  • Indian Institute of Technology Bombay (IN)
Venue
IEEE Transactions on Industry Applications
Published
2018-05
Volume
54
Issue
3
Pages
2821-2833
ISSN
  • 0093-9994 (ISSN-L)
  • 1939-9367
OpenAlex
W2884248839
Cited by
48
References
0
Citations by year
2025: 3 · 2024: 6 · 2023: 3 · 2022: 5 · 2021: 11 · 2020: 12 · 2019: 6 · 2018: 2
FWCI
4.80
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Industry Applications (publishedVersion)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
Keywords
islanded microgrids, droop control, network reconfiguration, mesh networks, radial networks, eigenvalue analysis, IEEE 33-bus system, IEEE 69-bus system, low-voltage microgrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review