CoChat

Battery Energy Storage for Seamless Transitions of Wind Generator in Standalone Microgrid

Chauhan, Priyesh J., Reddy, Bonthapalle Dastagiri, Bhandari, Saurabh, Panda, Sanjib Kumar · 2019 · IEEE Transactions on Industry Applications

The DOI matches its Crossref record; 16 of the 17 references it cites were found in a registry or an index.

Abstract

This paper presents a control scheme for a standalone microgrid having a nondispatchable fixed-pitch variable-speed wind generator (WG) and a battery energy storage (BES). The WG is directly interfaced at the point of common coupling (PCC) and the BES is interfaced at the PCC via a bidirectional dc-ac converter. The unique aspect of the control strategy is that the BES not only regulates the PCC voltage and frequency by active-reactive power compensations, but also ensures proper synchronization and disconnection of the WG during wind velocity variations. A simple control scheme, with only one interfacing converter and one voltage feedback loop, provides an uninterruptible electrical power supply to critical loads during various operating modes and enables seamless transition of the WG. Performance of the proposed system under all operating modes and transitions is tested through modeling and simulation in MATLAB/Simulink, and validated on laboratory test bench through implementation of the control algorithm on a DSP platform.

Overview

Integrity signals

Registry

Crossref · 10.1109/tia.2018.2863662

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 16 references

Research works printed but not linked: 4

  1. chauhan, 0, Seamless transitions of distributed generators in standalone microgrid for uninterrupted power supply, Proc 18th Workshop Control Model Power Electron, 1
  2. 2008, Small Hydro Action for the Promotion of Efficient Solutions, Micro and Mini Hydro Development on the Indian Subcontinent a Guide
  3. 1997, Small-scale hydro-power at Mae Ya, Thailand, Technical Brochure No 57
  4. varnado, 2009, Connecting to the grid: A guide to distributed generation interconnection issues, Interstate Renewable Energy Council

Cited by

See all 79

Metadata

Authors
Chauhan, P. J., Reddy, B. D., Bhandari, S., & Panda, S. K.
Affiliations
  • Institute of Infrastructure Technology Research and Management (IN)
  • ABB (India) (IN)
  • National University of Singapore (SG)
Venue
IEEE Transactions on Industry Applications
Published
2019-01
Volume
55
Issue
1
Pages
69-77
ISSN
  • 0093-9994 (ISSN-L)
  • 1939-9367
OpenAlex
W2907891415
Cited by
72
References
17
Citations by year
2026: 4 · 2025: 9 · 2024: 10 · 2023: 10 · 2022: 9 · 2021: 9 · 2020: 11 · 2019: 10
FWCI
4.64
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Industry Applications (publishedVersion)
Funders
  • Energy Market Authority (EMA), Singapore
  • National Research Foundation (NRF), Singapore
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
  • Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
Keywords
battery energy storage, islanded microgrids, wind turbine generator, seamless transition, bidirectional AC-DC converter, point of common coupling, voltage and frequency regulation, generator synchronization, generator disconnection, wind speed variation, uninterruptible power supply

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Battery Energy Storage for Seamless Transitions of Wind Generator in Standalone Microgrid. https://app.cochat.ai/papers/10.1109/tia.2018.2863662
The paper
Chauhan, P. J., Reddy, B. D., Bhandari, S., & Panda, S. K. (2019). Battery Energy Storage for Seamless Transitions of Wind Generator in Standalone Microgrid. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2018.2863662

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.