Battery Energy Storage for Seamless Transitions of Wind Generator in Standalone Microgrid
The DOI matches its Crossref record; 16 of the 17 references it cites were found in a registry or an index.
Abstract
This paper presents a control scheme for a standalone microgrid having a nondispatchable fixed-pitch variable-speed wind generator (WG) and a battery energy storage (BES). The WG is directly interfaced at the point of common coupling (PCC) and the BES is interfaced at the PCC via a bidirectional dc-ac converter. The unique aspect of the control strategy is that the BES not only regulates the PCC voltage and frequency by active-reactive power compensations, but also ensures proper synchronization and disconnection of the WG during wind velocity variations. A simple control scheme, with only one interfacing converter and one voltage feedback loop, provides an uninterruptible electrical power supply to critical loads during various operating modes and enables seamless transition of the WG. Performance of the proposed system under all operating modes and transitions is tested through modeling and simulation in MATLAB/Simulink, and validated on laboratory test bench through implementation of the control algorithm on a DSP platform.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Wind Energy Explained: Theory, Design and Application
Manwell, J. F., McGowan, J. G., & Rogers, A. L. (2002) · Wiley eBooks · doi:10.1002/0470846127 · Cited by 1,158
Emerging Power Quality Challenges Due to Integration of Renewable Energy Sources
Liang, X. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2626253 · Cited by 935
Bianchi, F. D., Mantz, R. J., & De Battista, H. (2007) · Advances in Industrial Control · doi:10.1007/1-84628-493-7 · Cited by 707
Distributed Power-Generation Systems and Protection
Blaabjerg, F., Yang, Y., Yang, D., & Wang, X. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2696878 · Cited by 671 · cited 1×
“photovoltaic-based generations are most widely adopted across the globe [3].”
BackgroundA Hybrid Power System Using Alternative Energy Facilities in Isolated Island
Senjyu, T., Nakaji, T., Uezato, K., & Funabashi, T. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837275 · Cited by 396 · cited 1×
“The evolution of power electronics and control technologies enables integration of one or more of the locally available wind/solar/hydro/biomass/tidal type energy-sourcesbased distributed generators into standalone microgrid [2].”
BackgroundFuture home uninterruptible renewable energy system with vehicle-to-grid technology
Cvetkovic, I., Thacker, T., Dong, D., Francis, G., Podosinov, V., Boroyevich, D., Wang, F., Burgos, R., Skutt, G., & Lesko, J. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316064 · Cited by 132 · cited 1×
“In [16], these issues for grid connection and islanding a wind/photovoltaic (PV) fed home power system supported by EV battery are presented.”
MethodSebastián, R. (2015) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2015.0435 · Cited by 126 · cited 1×
“The role of the BES in isolated wind (SEIG) diesel power system is demonstrated in [15] for active power compensation and frequency regulation in only wind-battery operation.”
BackgroundInduction generators for small hydro schemes
Ekanayake, J. B. (2002) · Power Engineering Journal · doi:10.1049/pe:20020202 · Cited by 112 · cited 1×
“Unlike a typical solar or WG, the interfacing converter is avoided in standalone selfexcited induction generator (SEIG) based variable speed WG when used with a BES [6]–[8].”
MethodQuinonez-Varela, G., & Cruden, A. J. (2008) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd:20060180 · Cited by 71 · cited 2×
“Management of individual energy sources is rather more critical for interactions within weak localized networks [12].”
BackgroundMethod
Research works printed but not linked: 4
- chauhan, 0, Seamless transitions of distributed generators in standalone microgrid for uninterrupted power supply, Proc 18th Workshop Control Model Power Electron, 1
- 2008, Small Hydro Action for the Promotion of Efficient Solutions, Micro and Mini Hydro Development on the Indian Subcontinent a Guide
- 1997, Small-scale hydro-power at Mae Ya, Thailand, Technical Brochure No 57
- varnado, 2009, Connecting to the grid: A guide to distributed generation interconnection issues, Interstate Renewable Energy Council
Cited by
Devassy, S., & Singh, B. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2984439 · Cited by 162
Photovoltaics performance improvement using different cooling methodologies: A state-of-art review
Kandeal, A. W., Thakur, A. K., Elkadeem, M. R., Elmorshedy, M. F., Ullah, Z., Sathyamurthy, R., & Sharshir, S. W. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.122772 · Cited by 142
State-of-Charge Balancing of Lithium-Ion Batteries With State-of-Health Awareness Capability
Xia, Z., & Abu Qahouq, J. A. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.3029755 · Cited by 115
Overview of Technical Specifications for Grid-Connected Microgrid Battery Energy Storage Systems
Khalid, A., Stevenson, A., & Sarwat, A. I. (2021) · IEEE Access · doi:10.1109/access.2021.3132223 · Cited by 114
“BESSs can also be used to facilitate a smooth transition for DGs to synchronize with the adjacent grid system, as shown in [165].”
MethodEskandari, M., Rajabi, A., Savkin, A. V., Moradi, M. H., & Dong, Z. Y. (2022) · Journal of Energy Storage · doi:10.1016/j.est.2022.105627 · Cited by 102
Metadata
- Authors
- Chauhan, P. J., Reddy, B. D., Bhandari, S., & Panda, S. K.
- Affiliations
- Institute of Infrastructure Technology Research and Management (IN)
- ABB (India) (IN)
- National University of Singapore (SG)
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2019-01
- Volume
- 55
- Issue
- 1
- Pages
- 69-77
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2907891415
- Cited by
- 72
- References
- 17
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 10 · 2023: 10 · 2022: 9 · 2021: 9 · 2020: 11 · 2019: 10
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Funders
- Energy Market Authority (EMA), Singapore
- National Research Foundation (NRF), Singapore
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
- Keywords
- battery energy storage, islanded microgrids, wind turbine generator, seamless transition, bidirectional AC-DC converter, point of common coupling, voltage and frequency regulation, generator synchronization, generator disconnection, wind speed variation, uninterruptible power supply
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Battery Energy Storage for Seamless Transitions of Wind Generator in Standalone Microgrid. https://app.cochat.ai/papers/10.1109/tia.2018.2863662
- The paper
- Chauhan, P. J., Reddy, B. D., Bhandari, S., & Panda, S. K. (2019). Battery Energy Storage for Seamless Transitions of Wind Generator in Standalone Microgrid. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2018.2863662
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.