Battery Energy Storage for Seamless Transitions of Wind Generator in Standalone Microgrid
The DOI matches its Crossref record; 16 of the 17 references it cites were found in a registry or an index.
Abstract
This paper presents a control scheme for a standalone microgrid having a nondispatchable fixed-pitch variable-speed wind generator (WG) and a battery energy storage (BES). The WG is directly interfaced at the point of common coupling (PCC) and the BES is interfaced at the PCC via a bidirectional dc-ac converter. The unique aspect of the control strategy is that the BES not only regulates the PCC voltage and frequency by active-reactive power compensations, but also ensures proper synchronization and disconnection of the WG during wind velocity variations. A simple control scheme, with only one interfacing converter and one voltage feedback loop, provides an uninterruptible electrical power supply to critical loads during various operating modes and enables seamless transition of the WG. Performance of the proposed system under all operating modes and transitions is tested through modeling and simulation in MATLAB/Simulink, and validated on laboratory test bench through implementation of the control algorithm on a DSP platform.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Wind Energy Explained: Theory, Design and Application
Manwell, J. F., McGowan, J. G., & Rogers, A. L. (2002) · Wiley eBooks · doi:10.1002/0470846127 · Cited by 1,158
Emerging Power Quality Challenges Due to Integration of Renewable Energy Sources
Liang, X. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2626253 · Cited by 935
Bianchi, F. D., Mantz, R. J., & De Battista, H. (2007) · Advances in Industrial Control · doi:10.1007/1-84628-493-7 · Cited by 707
Distributed Power-Generation Systems and Protection
Blaabjerg, F., Yang, Y., Yang, D., & Wang, X. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2696878 · Cited by 671 · cited 1×
“photovoltaic-based generations are most widely adopted across the globe [3].”
BackgroundA Hybrid Power System Using Alternative Energy Facilities in Isolated Island
Senjyu, T., Nakaji, T., Uezato, K., & Funabashi, T. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837275 · Cited by 396 · cited 1×
“The evolution of power electronics and control technologies enables integration of one or more of the locally available wind/solar/hydro/biomass/tidal type energy-sourcesbased distributed generators into standalone microgrid [2].”
BackgroundFuture home uninterruptible renewable energy system with vehicle-to-grid technology
Cvetkovic, I., Thacker, T., Dong, D., Francis, G., Podosinov, V., Boroyevich, D., Wang, F., Burgos, R., Skutt, G., & Lesko, J. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316064 · Cited by 132 · cited 1×
“In [16], these issues for grid connection and islanding a wind/photovoltaic (PV) fed home power system supported by EV battery are presented.”
MethodSebastián, R. (2015) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2015.0435 · Cited by 126 · cited 1×
“The role of the BES in isolated wind (SEIG) diesel power system is demonstrated in [15] for active power compensation and frequency regulation in only wind-battery operation.”
BackgroundInduction generators for small hydro schemes
Ekanayake, J. B. (2002) · Power Engineering Journal · doi:10.1049/pe:20020202 · Cited by 112 · cited 1×
“Unlike a typical solar or WG, the interfacing converter is avoided in standalone selfexcited induction generator (SEIG) based variable speed WG when used with a BES [6]–[8].”
MethodQuinonez-Varela, G., & Cruden, A. J. (2008) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd:20060180 · Cited by 71 · cited 2×
“Management of individual energy sources is rather more critical for interactions within weak localized networks [12].”
BackgroundMethod
Research works printed but not linked: 4
- chauhan, 0, Seamless transitions of distributed generators in standalone microgrid for uninterrupted power supply, Proc 18th Workshop Control Model Power Electron, 1
- 2008, Small Hydro Action for the Promotion of Efficient Solutions, Micro and Mini Hydro Development on the Indian Subcontinent a Guide
- 1997, Small-scale hydro-power at Mae Ya, Thailand, Technical Brochure No 57
- varnado, 2009, Connecting to the grid: A guide to distributed generation interconnection issues, Interstate Renewable Energy Council
Cited by
Devassy, S., & Singh, B. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2984439 · Cited by 162
Photovoltaics performance improvement using different cooling methodologies: A state-of-art review
Kandeal, A. W., Thakur, A. K., Elkadeem, M. R., Elmorshedy, M. F., Ullah, Z., Sathyamurthy, R., & Sharshir, S. W. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.122772 · Cited by 142
State-of-Charge Balancing of Lithium-Ion Batteries With State-of-Health Awareness Capability
Xia, Z., & Abu Qahouq, J. A. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.3029755 · Cited by 115
Overview of Technical Specifications for Grid-Connected Microgrid Battery Energy Storage Systems
Khalid, A., Stevenson, A., & Sarwat, A. I. (2021) · IEEE Access · doi:10.1109/access.2021.3132223 · Cited by 115
“BESSs can also be used to facilitate a smooth transition for DGs to synchronize with the adjacent grid system, as shown in [165].”
MethodEskandari, M., Rajabi, A., Savkin, A. V., Moradi, M. H., & Dong, Z. Y. (2022) · Journal of Energy Storage · doi:10.1016/j.est.2022.105627 · Cited by 102
Chishti, F., Murshid, S., & Singh, B. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2923575 · Cited by 59
“APPENDIX A. SG parameters: 415 V, 5 hp, Rs = 3.1Ω, poles = 4, field excitation voltage: 220 V. B. DC motor: 220 V, 19 A, 5 hp. C. Wind speed range: 7–12 m/s. D. DC-link voltage: Vdc : 400 V. E. Solar PV array: 2.4 kW. F. Parameters of BES: 240 V, 56 Ah.”
BackgroundInfluentialKumar, J., Parthasarathy, C., Västi, M., Laaksonen, H. J. J., Shafie‐khah, M., & Kauhaniemi, K. (2020) · Energies · doi:10.3390/en13020317 · Cited by 58
“The accurate modelling of battery packs for stationary energy storage grid applications has been minimal, as the majority of the literature considers battery systems as an ideal DC voltage source [25] or utilizes mathematical modelling techniques.”
BackgroundDesign of a Hybrid Energy System with Energy Storage for Standalone DC Microgrid Application
Juma, M., Mwinyiwiwa, B. M. M., Msigwa, C. J., & Mushi, A. T. (2021) · Energies · doi:10.3390/en14185994 · Cited by 57
“[22] presented a control scheme for a wind generator (WG) coupled with a battery energy storage.”
BackgroundBao, Z., Nie, J., Lin, H., Li, Z., Gao, K., He, Z., & Gao, M. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3393477 · Cited by 48
“To enhance network training efficiency and predictive capabilities, this article employs the Pearson correlation coefficient (PCC) to assess the strength and direction of the linear correlation between the input raw data, and SOC and SOE [34], as shown in Fig.”
Kundu, S., Singh, M., & Giri, A. K. (2023) · Electrical Engineering · doi:10.1007/s00202-023-01979-0 · Cited by 39
Performance augmentation of PV panels using phase change material cooling technique: A review
Maghrabie, H. M., Mohamed, A. S. A., Fahmy, A. M., & Samee, A. A. A. (2021) · SVU-International Journal of Engineering Sciences and Applications · doi:10.21608/svusrc.2021.87202.1013 · Cited by 34
“Generally, 67% of electricity is generated by fuel-fired power plants, which emit hazardous pollutants that contribute to global warming [3].”
BackgroundControl algorithm for coordinated operation of wind-solar microgrid standalone generation system
Kundu, S., Singh, M., & Giri, A. K. (2022) · Energy Sources Part A Recovery Utilization and Environmental Effects · doi:10.1080/15567036.2022.2143943 · Cited by 34
“Many control strategies exist for voltage and frequency regulations in standalone energy systems (Chauhan et al. 2019; Giri et al. 2019; Kewat, Singh, and Hussain 2018; Kumar Kalla et al. 2018).”
BackgroundSeamless Control of Solar PV Grid Interfaced System With Islanding Operation
Singh, S., Kewat, S., Singh, B., Panigrahi, B. K., & Kushwaha, M. K. (2019) · IEEE Power and Energy Technology Systems Journal · doi:10.1109/jpets.2019.2929300 · Cited by 32
Patel, T., & Chauhan, P. J. (2023) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2023.3341950 · Cited by 27
“As indicated in [6], among the aforesaid two approaches for the BES VSC control, a full-time GF operation of the VSC provides better plug-and-play performance of the WG.”
BackgroundResultSelf-citationPV-Wind-Battery Based Standalone Microgrid System with MPPT for Green and Sustainable Future
Habib, H. U. R., Wang, S., & Aziz, M. T. (2019) · International Conference on Power and Energy Systems (ICPES) · doi:10.1109/icpes47639.2019.9105395 · Cited by 24
“Standalone microgrid ensures uninterruptible power supply to critical load (CL) during PV-Wind power fluctuation [1].”
BackgroundRecent techniques for cooling of concentrated photovoltaic thermal systems
Hosseini, F., Sheikholeslami, M., & Ghasemian, M. (2024) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-024-12984-1 · Cited by 20
“Fossil fuels generate about two-thirds of the electricity needed, which results in environmental damage and climate change [1].”
Lithium-ion BESS Integration for Smart Grid Applications - ECM Modelling Approach
Parthasarathy, C., Hafezi, H., & Laaksonen, H. J. J. (2020) · IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT) · doi:10.1109/isgt45199.2020.9087741 · Cited by 18
“Accurate modelling of battery packs for energy storage applications have been minimal where majority of the literature considers battery systems as an ideal DC voltage source [3] or by utilizing mathematical modelling techniques [4].”
BackgroundA Comparative Analysis of Supporting Policies for Solar PV systems in the Baltic Countries
Petrichenko, L., Zemīte, L., Sauhats, A. S., Klementavičius, A., & Grickevics, K. (2019) · IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) · doi:10.1109/eeeic.2019.8783838 · Cited by 17
“A number of studies discuss cases of using PV technology and storage systems at highprice and low-price periods [29, 30].”
BackgroundParthasarathy, C., Laaksonen, H. J. J., & Halagi, P. (2021) · IEEE PES Innovative Smart Grid Technologies - Asia (ISGT Asia) · doi:10.1109/isgtasia49270.2021.9715566 · Cited by 15
“Li-ion batteries when utilised for power system studies are modelled as an ideal DC [16] or by using empirical/mathbased models [17],[18].”
MethodBrushless Synchronous Generator-Unidirectional Rectifier for Offshore Wind Energy Conversion System
Bhattacherjee, H., Mukherjee, D., Vuyyuru, U., & Chakraborty, C. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3131523 · Cited by 14
Adaptive Position Observer for Multimode Wind-BES Based Microgrid Interfaced to Distribution Network
Pradhan, S., Singh, B., & Panigrahi, B. K. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3170003 · Cited by 14
Abu Qahouq, J. (2024) · Batteries · doi:10.3390/batteries10100368 · Cited by 13
An Intelligent Energy Management System for Grid Connected DFIG based Wind System
Raghavendran, C. R., Sadees, M., Roselyn, J. P., & Devaraj, D. (2019) · IEEE International Conference on Intelligent Techniques in Control, Optimization and Signal Processing (INCOS) · doi:10.1109/incos45849.2019.8951316 · Cited by 12
“The papers cited above EMSs have a very complex structure and design complexity of three control levels are [10].”
BackgroundDeepu Vijay, M., Singh, B., & Bhuvaneswari, G. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.3024156 · Cited by 11
“load under the standalone condition when the power generation from WEGS is inadequate [11].”
BackgroundTyagi, S., Singh, B., & Das, S. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3261863 · Cited by 9
“A battery energy storage system (BESS) based grid forming converter is presented in [9] where the voltage and frequency are regulated by the battery based inverter.”
MethodMoon, J.-H., Lee, H. M., Lee, J.-H., Park, S., & Kang, F. (2021) · IEEE Access · doi:10.1109/access.2021.3095905 · Cited by 9
Ngamroo, I., & Surinkaew, T. (2022) · IET Renewable Power Generation · doi:10.1049/rpg2.12576 · Cited by 9
Hasan, K., Othman, M. M., Meraj, S. T., Rahman, M. S., Lipu, M. S. H., & Sarker, M. R. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.109256 · Cited by 8
Presynchronization of Weak Source in Microgrid
Patel, T., & Chauhan, P. J. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3383923 · Cited by 8
Self-citationElmorshedy, M. F., Allam, S. M., & Rashad, E. M. (2020) · Australian Journal of Electrical & Electronics Engineering · doi:10.1080/1448837x.2020.1783087 · Cited by 7
Improving the performance of a photovoltaic panel using locally manufactured phase change materials
Kadhim, H. K., Aftan, A. O., & Wadday, A. G. (2024) · AIP conference proceedings · doi:10.1063/5.0200262 · Cited by 7
Neelagiri, S., Usha, P., & Biradar, S. (2025) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v16.i3.pp1991-2004 · Cited by 6
“The control and operation of microgrids integrated with wind turbines and HESS are explained in [17].”
Microgrid synchronization using power offset through a central controller
Syahril, M., Roslan, M. A., & Ismail, B. (2020) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1432/1/012019 · Cited by 6
Hybrid Renewable Microgrid System Based DC-bus Scheme for Residential Load Applications
Elmorshedy, M. F., Kotb, K. M., & Dan, A. M. (2019) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2019.8922530 · Cited by 6
“Although the conventional power generating ways which utilize the customary types of fuel contributes about 67% of electricity production around the world, it is considered the main supplier of harmful emissions that causes the global warming [3].”
BackgroundAbouassy, A. M., Mansour, D. A., Asano, T., & Megahed, T. F. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3578709 · Cited by 5
Lithium-ion BESS integration for smart grid applications : ECM modelling approach
Parthasarathy, C., Hafezi, H., & Laaksonen, H. J. J. (2020) · Scopus · Cited by 5
Прасад, Т., Kumar, S., Singh, B., Kurm, S., & Modi, G. (2025) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2025.3606929 · Cited by 4
“By dynamically managing charging and discharging modes based on real-time demand, the system ensures stable power supply, grid stabilization, and peak load management, making it a highly innovative solution for future sustainable energy systems [10], [11], [12], [13], [14].”
AISMC for Islanded Operation of Wind Driven SEIG Based DC Nanogrid
Kumar, S., Mukkapati, A. B. K., Krishnasamy, V., & Kaur, R. (2019) · National Power Electronics Conference (NPEC) · doi:10.1109/npec47332.2019.9034745 · Cited by 4
“Among the various renewable resources wind and solar are used for powering a nanogrid [1].”
BackgroundRazzaq, S. A., & Jayasankar, V. (2023) · International Journal of Applied Power Engineering (IJAPE) · doi:10.11591/ijape.v12.i1.pp24-36 · Cited by 4
Innovative cooling techniques used for performance enhancement of photovoltaic systems
Ghasemian, M., Sheikholeslami, M., & Dehghan, M. (2023) · Waves in Random and Complex Media · doi:10.1080/17455030.2023.2226232 · Cited by 4
“Approximately two-thirds of the required electricity is provided by fossil fuels, which leads to environmental pollution and global warming [1].”
Kumar, A., Kewat, S., Singh, B., & Jain, R. (2020) · Journal of The Institution of Engineers (India) Series B · doi:10.1007/s40031-020-00433-0 · Cited by 4
A topological overview of microgrids: from maturity to the future
Erenoğlu, A. K., Sancar, S., Erdinç, O., & Bağrıyanık, M. (2021) · TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES · doi:10.3906/elk-2012-80 · Cited by 4
Wind - Battery Controller Based Standalone Alternating Current Microgrid Applications
Mudigondla, R., Reddy, B. S. G., Vinitha, B., Vishwateja, P., Kamble, A., & Chenchireddy, K. (2023) · International Conference on Sustainable Computing and Data Communication Systems (ICSCDS) · doi:10.1109/icscds56580.2023.10104926 · Cited by 3
“[5] Also, a University of Michigan study investigated the potential of freestanding.[6] AC micro grids powered by wind and batteries lower carbon emissions and enhance access to energy in poor nations.”
BackgroundSelf-citationA New Optimization Method for Improving the Performance of Photovoltaic System
Aftan, A. O. (2022) · International Conference on Current Research in Engineering and Science Applications (ICCRESA) · doi:10.1109/iccresa57091.2022.10352491 · Cited by 3
“Typically, fuel-fired power plants produce 67% of the nation's electricity, and their dangerous pollution wastes push global warming [3].”
BackgroundLin, Y., Ni, W., Wang, B., Sheng, Y., Zhang, Y., Zhuang, T., Guo, Q., & Sun, H. (2024) · Asia Energy and Electrical Engineering Symposium (AEEES) · doi:10.1109/aeees61147.2024.10545005 · Cited by 3
“It is beneficial to play the role of active and reactive power support from ESSs during the fault period [22].”
BackgroundHabib, H. U. R., Wang, S., & Elmorshedy, M. F. (2019) · International Conference on Intelligent Green Building and Smart Grid · doi:10.1109/igbsg.2019.8886215 · Cited by 3
“In all transition modes, standalone microgrid ensures uninterruptible power supply to critical load (CL) during wind power fluctuation [1].”
BackgroundPermanence Improvement of a Local Energy Production System Including Unbalanced Loading
Kotb, K. M., Elmorshedy, M. F., & Dan, A. M. (2019) · IEEE International Conference and Workshop Óbuda on Electrical and Power Engineering (CANDO-EPE) · doi:10.1109/cando-epe47959.2019.9110974 · Cited by 3
“Despite the traditional systems contribute around three-quarters of the world’s electricity, it is reasoned as the number one purveyor of hurtful emissions and noxious gases [3].”
BackgroundAn Online Prime Dual Approach for Energy Cost Management in Standalone Microgrid with Optimized PMU
Lingan, S., & Umapathy, P. S. (2023) · Electric Power Components and Systems · doi:10.1080/15325008.2023.2199749 · Cited by 3
“[1] No No No Unavailable Unavailable No Unavailable Yes [2] Unavailable Unavailable Unavailable Yes No Unavailable Yes Unavailable [3] Yes Unavailable Unavailable Unavailable No No Yes Unavailable [4] Unavailable Unavailable No No Yes No Yes No [5] Unavailable No Yes No Unavailable No No No [6] Unavailable No No Unava…”
BackgroundGrid control strategy of wind turbines based on LADRC voltage control
Li, W., Zhou, X., Meng, Y., & You, J. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2771/1/012026 · Cited by 3
Li, Z., & Xu, J. (2024) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec61255.2024.10922319 · Cited by 3
“The mechanism through which GFM wind turbines contribute to enhancing wind farm stability under weak electrical networks is validated from a reactive voltage support perspective in reference [8].”
A wind and solar based ac micro grid with optimized power quality for local non-linear loads
Gopi, P., Lalitha, M. P., & Bhanu, S. A. J. (2021) · International Conference on Technology and Policy in Energy and Electric Power (ICT-PEP) · doi:10.1109/ict-pep53949.2021.9600903 · Cited by 3
Retraction: Performance improvement of the solar PV system-based phase change material: A review
Kadhim, H. K., Aftan, A. O., & Wadday, A. G. (2023) · AIP conference proceedings · doi:10.1063/5.0182015 · Cited by 3
RetractedHabib, H. U. R., Wang, S., Elmorshedy, M. F., Hussien, M. G., & Waqar, A. (2019) · IEEE International Conference on Advanced Power System Automation and Protection (APAP) · doi:10.1109/apap47170.2019.9507385 · Cited by 2
Grid Forming Converter Having Power Sharing and Synchronization Capability With DFIG Based WECS
Tyagi, S., & Singh, B. (2022) · IEEE Global Conference on Computing, Power and Communication Technologies (GlobConPT) · doi:10.1109/globconpt57482.2022.9938186 · Cited by 2
“A battery energy storage system (BESS) based grid forming converter is presented in [2] where the voltage and frequency are regulated by the battery based inverter.”
MethodImproved Impedance Model of Grid-Forming ESS for Interactive and Self-Stability Analysis
Gu, Y., Zhu, R., & Gu, Y. (2024) · Asia Conference on Power and Electrical Engineering (ACPEE) · doi:10.1109/acpee60788.2024.10532266 · Cited by 2
“The GFM operation of power converters has been widely used in uninterruptible power supplier (UPS) system [5], where the UPS is equivalent to a slack bus with a constant voltage magnitude and frequency, because the UPS-fed system operates in the islanding case.”
MethodPradhan, S., Singh, B., & Panigrahi, B. K. (2020) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes49360.2020.9379432 · Cited by 2
Control of Wind-Battery Based Microgrid With Seamless Synchronization to Grid/DG Set
Kewat, S., & Singh, B. (2020) · International Conference on Power, Instrumentation, Control and Computing (PICC) · doi:10.1109/picc51425.2020.9362497 · Cited by 2
“Therefore, to increase the reliability of the wind-based generation system, the storage battery is integrated into the generation unit [5].”
BackgroundLin, Y., Wang, B., Guo, Q., Zhao, H., & Sun, H. (2024) · arXiv (Cornell University) · doi:10.48550/arxiv.2402.01523 · Cited by 2
“It is beneficial to play the role of active and reactive power support from ESSs during the fault period [25].”
BackgroundSteady State and Short Circuit Analysis of Microgrid with Renewables and EVs Using ETAP
Mondal, S., Bohre, A. K., Kolhe, M. L., & Thakkar, J. (2024) · Lecture notes in electrical engineering · doi:10.1007/978-981-97-0763-8_42 · Cited by 1
Stability Analysis Method for High Proportion Renewable Energy Grid Based on Transient Security
Ye, Y., Hao, Y., Zhou, Z., Zhou, Z., Liao, H., & Liang, S. (2025) · International Conference on Electrical Technology and Automatic Control (ICETAC) · doi:10.1109/icetac65964.2025.11144261 · Cited by 1
“It depends on reactive power balance, closely tied to load characteristics (e.g., voltage-reactive response) and generator voltage regulation [10] .”
Characterization and modelling of Lithium-ion Batteries for Grid Applications
Halagi, P. (2021) · Osuva (University of Vaasa)
Design and Modelling of Multilevel Inverter for Micro Wind Energy Generation System
Revathy, R., Priya, R. M., & Priyanka, S. (2021) · International Conference on System, Computation, Automation and Networking (ICSCAN) · doi:10.1109/icscan53069.2021.9526375
“Priyesh J. Chauhan et al [13] proposes the battery energy storage for seamless transitions of wind generator in standalone micro grid.”
BackgroundLokesh, D., & Senthil Singh, C. (2022) · ECS Transactions · doi:10.1149/10701.2791ecst
Design and Simulation of DFIG based Wind Energy System using AI EMS
Rubini, S., & Sankar, P. P. (2022) · International Journal for Research in Applied Science and Engineering Technology · doi:10.22214/ijraset.2022.43614
Gopi, P., Lalitha, M. P., & Bhanu, S. A. J. (2022) · Lecture notes in electrical engineering · doi:10.1007/978-981-19-1111-8_74
Seamless Transitions of Variable-Speed Wind Generator in Standalone Microgrid
Patel, T., & Chauhan, P. J. (2022) · IEEE Power India International Conference · doi:10.1109/piicon56320.2022.10045293
“A scalarbased GF control has been used in an earlier method, which is easy to implement but it has the inherent coupling between the voltage and frequency [4].”
BackgroundMethodSelf-citationZhang, X., Xia, D., Zhang, H., & Wang, J. (2023) · Frontiers in Energy Research · doi:10.3389/fenrg.2023.1309587
Parmar, D. B., & Giri, A. K. (2023) · IEEE Region Humanitarian Technology Conference · doi:10.1109/r10-htc57504.2023.10461777
“Control of Battery Energy Storage for Seamless Transitions of Wind Generator in a Standalone Microgrid presents a control structure for a standalone microgrid having a non-dispatchable fixed-pitch variable-speed wind generator and a battery energy storage [6-7].”
BackgroundBattery Cluster Grid-Connected Balancing Control Strategy Based on Series Power Converter
Zhu, Y., Li, G., Wu, H., & Xu, D. (2024) · IEEE Information Technology, Networking, Electronic and Automation Control Conference (ITNEC) · doi:10.1109/itnec60942.2024.10733208
“In the large-scale application of energy storage systems, Lithium-ion battery energy storage has long service life and high flexibility, and is widely used in high-voltage DC energy storage systems, such as electric vehicles, hybrid electric vehicles and microgrids [1~2].”
BackgroundNie, X., Wang, X., Li, T., Lin, X., & Meng, X. (2025) · International Conference on Electrical Drives, Power Electronics & Engineering (EDPEE) · doi:10.1109/edpee65754.2025.00066
“…out as an indispensable core component in large-scale energy storage, electric vehicles, portable electronic devices, and other fields due to its significant advantages such as high energy/power density, long cycle life, no memory effect, low self discharge rate, and environmental friendliness [4].”
Stand-alone Doubly-Fed induction generator system using single inverter and battery storage
Sekhar, N., & Maruthi, G. D. (2025) · Australian Journal of Electrical & Electronics Engineering · doi:10.1080/1448837x.2025.2553953
Kouser, S., Dheep, G. R., & Bansal, R. C. (2025) · Smart Grids and Sustainable Energy · doi:10.1007/s40866-025-00309-6
PLL-Based Plug-and-Play of Wind Generator in Standalone Microgrid
Patel, T., & Chauhan, P. J. (2025) · North American Power Symposium (NAPS) · doi:10.1109/naps66256.2025.11272214
“Therefore, the synchronization requirements must be satisfied before transition of any RES [3], [4].”
Self-citationAbouassy, A. M., Mansour, D. A., & Megahed, T. F. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-24722-4.00013-6
Stability analysis method for grid-forming wind turbine and energy storage interconnected system
Li, X. (2025) · IEEE International Power Electronics and Application Symposium (PEAS) · doi:10.1109/peas66638.2025.11403237
“Most of the existing projects use grid-forming energy storage (GFM-ES) converters to assist the grid-following renewable energy to improve the system stability [4].”
Lin, Y., Xie, H., Liu, H., Lin, Z., Zhong, J., & Li, Z. (2025) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei268505.2025.11425351
“Applying GFM technology to energy storage converters facilitates the active and reactive power support role of energy storage during faults, enhancing the safety of renewable energy grid integration and system stability [17].”
Dual-Mode Seamless Transition for Hybrid Distribution Transformer With Energy Storage
Xue, Y., Liu, Y., Wen, Q., Deng, H., Liang, D., Yu, L., & Zhang, L. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2026.3677681
“In [25], a control scheme is proposed for a standalone microgrid with a nondispatchable fixed-pitch variable-speed wind generator and a battery energy storage, provide uninterruptible power supply during various transitions.”
Pushpalatha, B. M., Nitesh, D., Choraria, A. J., Prasad, R. D., Kumar, J. N. A., & Raju, P. S. K. (2026) · IEEE International Conference on Renewable Energy and Sustainable E-Mobility (RESEM) · doi:10.1109/resem70152.2026.11721947
Metadata
- Authors
- Chauhan, P. J., Reddy, B. D., Bhandari, S., & Panda, S. K.
- Affiliations
- Institute of Infrastructure Technology Research and Management (IN)
- ABB (India) (IN)
- National University of Singapore (SG)
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2019-01
- Volume
- 55
- Issue
- 1
- Pages
- 69-77
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2907891415
- Cited by
- 72
- References
- 17
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 10 · 2023: 10 · 2022: 9 · 2021: 9 · 2020: 11 · 2019: 10
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Funders
- Energy Market Authority (EMA), Singapore
- National Research Foundation (NRF), Singapore
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
- Keywords
- battery energy storage, islanded microgrids, wind turbine generator, seamless transition, bidirectional AC-DC converter, point of common coupling, voltage and frequency regulation, generator synchronization, generator disconnection, wind speed variation, uninterruptible power supply
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.