Voltage Control in Low-Voltage Grids Using Distributed Photovoltaic Converters and Centralized Devices
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper studies the application of distributed and centralized solutions for voltage control in low voltage (LV) grids with high photovoltaic (PV) penetration. In traditional LV grids, the coordination of distributed PV converters and a centralized device would require massive investments in new communication and control infrastructures. The alternative of exploiting distributed PV converters for voltage control is discussed, showing that it can help to stabilize the voltage in the grid connection points also without coordination between them and/or with a centralized unit. The goal of this paper is to investigate how the setup of the voltage controllers inside PV inverters affects the operation of these controllers taking into account the limits for reactive power injection. In addition, the interaction of distributed PV converters with centralized devices (static var compensators and on load tap changers) is analyzed to assess whether additional benefits may come in these cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Demirok, E., González, P. C., Frederiksen, K. H. B., Sera, D., Rodriguez, P., & Teodorescu, R. (2011) · IEEE Journal of Photovoltaics · doi:10.1109/jphotov.2011.2174821 · Cited by 530
Cited by
Heidari Yazdi, S. S., Rahimi, T., Khadem Haghighian, S., Gharehpetian, G. B., & Bagheri, M. (2022) · Frontiers in Energy Research · doi:10.3389/fenrg.2022.920654 · Cited by 20
Ciocia, A., Chicco, G., & Spertino, F. (2020) · 2020 International Conference on Smart Energy Systems and Technologies (SEST) · doi:10.1109/sest48500.2020.9203231 · Cited by 11
“In [9], tviol represents the theoretical time for which the maximum overvoltage is accepted.”
BackgroundMethodSelf-citationLoad-Dependent Active Thermal Control of Grid-Forming Converters
Andresen, M., De Carne, G., & Liserre, M. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2966573 · Cited by 10
“To reduce the thermal stress for the semiconductors, the grid-forming converter can exploit its voltage control feature to shape the load consumption in a controlled way and, thus, to damp the power variations at grid-forming converter level [8]–[10].”
BackgroundZeng, F., Han, H., Miao, H., Pan, Y., Yuan, X., & Lyu, S. (2025) · Energy Engineering · doi:10.32604/ee.2024.056380 · Cited by 7
Metadata
- Authors
- Ciocia, A., Boicea, V. A., Chicco, G., Di Leo, P., Mazza, A., Pons, E., Spertino, F., & Hadj-Said, N.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2019-01
- Volume
- 55
- Issue
- 1
- Pages
- 225-237
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2891677215
- Cited by
- 54
- References
- 1
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.