The DOI matches its Crossref record.
Active Damping Control of a High-Power PWM Current-Source Rectifier for Line-Current THD Reduction
Abstract
The use of active damping to reduce the total harmonic distortion (THD) of the line current for medium-voltage (2.3-7.2 kV) high-power pulsewidth-modulation (PWM) current-source rectifiers is investigated. The rectifier requires an LC filter connected at its input terminals, which constitutes an LC resonant mode. The lightly damped LC filter is prone to series and parallel resonances when tuned to a system harmonic either from the utility or from the PWM rectifier. These issues are traditionally addressed at the design stage by properly choosing the filter resonant frequency. This approach may result in a limited performance since the LC resonant frequency is a function of the power system impedance, which usually varies with power system operating conditions. In this paper, an active damping control method is proposed for the reduction in line current THD of high-power current-source rectifiers operating at a switching frequency of only 540 Hz. Two types of LC resonances are investigated: the parallel resonance excited by harmonic currents drawn by the rectifier and the series resonance caused by harmonic pollution in the source voltage. It is demonstrated through simulation and experiments that the proposed active damping control can effectively reduce the line-current THD caused by both parallel and series resonances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Virtual-Impedance-Based Control for Voltage-Source and Current-Source Converters
Wang, X., Li, Y. W., Blaabjerg, F., & Loh, P. C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2382565 · Cited by 670
Investigation and Active Damping of Multiple Resonances in a Parallel-Inverter-Based Microgrid
He, J., Li, Y. W., Bosnjak, D., & Harris, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2195032 · Cited by 466
Rahimi, A. M., & Emadi, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2013748 · Cited by 461
Control and Resonance Damping of Voltage-Source and Current-Source Converters With $LC$ Filters
Li, Y. W. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009562 · Cited by 372
Saber, C., Labrousse, D., Revol, B., & Gascher, A. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2500958 · Cited by 73
Metadata
- Authors
- Wiseman, J. C., & Wu, B.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2005-06
- Volume
- 52
- Issue
- 3
- Pages
- 758-764
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2498362500
- Cited by
- 170
- References
- 0
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Active Damping Control of a High-Power PWM Current-Source Rectifier for Line-Current THD Reduction. https://app.cochat.ai/papers/10.1109/tie.2005.843939
- The paper
- Wiseman, J. C., & Wu, B. (2005). Active Damping Control of a High-Power PWM Current-Source Rectifier for Line-Current THD Reduction. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2005.843939
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.