Sensorless control of permanent-magnet synchronous motors using online parameter identification based on system identification theory
Open accessAbstract
An online parameter identification method and sensorless control using identified parameters were realized in surface and interior permanent-magnet synchronous motors (SPMSMs and IPMSMs, respectively). As this method does not use rotor position or velocity to identify motor parameters, the identified parameters are not affected by position estimation error under sensorless control. The proposed method can be applied to all kinds of synchronous motors. The effectiveness of the proposed method was verified by experiments in both SPMSMs and IPMSMs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
System identification—Theory for the user
Sinha, N. K. (1989) · Automatica · doi:10.1016/0005-1098(89)90019-8 · Cited by 9,184
Golomb, S. W. (2017) · WORLD SCIENTIFIC eBooks · doi:10.1142/9361 · Cited by 2,180
Cattermole, K. W. (1968) · Electronics and Power · doi:10.1049/ep.1968.0141 · Cited by 1,319
Sensorless control strategy for salient-pole PMSM based on extended EMF in rotating reference frame
Morimoto, S., Kawamoto, K., Sanada, M., & Takeda, Y. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.800777 · Cited by 680
Sensorless control of AC machines at low speed and standstill based on the "INFORM" method
Schroedl, M. (2002) · IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting · doi:10.1109/ias.1996.557028 · Cited by 618
Kim, H., Harke, M. C., & Lorenz, R. D. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.818966 · Cited by 301
Sensorless rotor position estimation of an interior permanent-magnet motor from initial states
Ha, J.-I., Ide, K., Sawa, T., & Sul, S.-K. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.811781 · Cited by 236
Cited by
Position Sensorless Permanent Magnet Synchronous Machine Drives—A Review
Wang, G., Valla, M., & Solsona, J. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2955409 · Cited by 855
A High-Speed Sliding-Mode Observer for the Sensorless Speed Control of a PMSM
Kim, H., Son, J., & Lee, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098357 · Cited by 733
Online Parameter Estimation and Adaptive Control of Permanent-Magnet Synchronous Machines
Underwood, S. J., & Husain, I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036029 · Cited by 502
Kazmi, S. M. R., Goto, H., Guo, H.-J., & Ichinokura, O. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2044732 · Cited by 410
Shi, Y., Sun, K., Huang, L., & Li, Y. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2168792 · Cited by 353
Metadata
- Authors
- Ichikawa, S., Tomita, M., Doki, S., & Okuma, S.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2006-04
- Volume
- 53
- Issue
- 2
- Pages
- 363-372
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2166624756
- Cited by
- 383
- References
- 8
- FWCI
- 14.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.