The DOI matches its Crossref record.
FPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion Systems
Open accessAbstract
This paper discusses the design, implementation, experimental validation, and performances of a field-programmable gate array (FPGA)-based real-time power converter failure diagnosis for three-leg fault tolerant converter topologies used in wind energy conversion systems (WECSs). The developed approach minimizes the time interval between the fault occurrence and its diagnosis. We demonstrated the possibility to detect a faulty switch in less than 10 mus by using a diagnosis simultaneously based on a ldquotime criterionrdquo and a ldquovoltage criterion.rdquo To attain such a short detection time, an FPGA fully digital implementation is used. The performances of the proposed FPGA-based fault detection method are evaluated for a new fault tolerant back-to-back converter topology suited for WECS with doubly fed induction generator (DFIG). We examine the failure diagnosis method and the response of the WECS when one of the power switches of the fault tolerant back-to-back converter is faulty. The experimental failure diagnosis implementation based on ldquoFPGA in the looprdquo hardware prototyping verifies the performances of the fault tolerant WECS with DFIG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 27
- 10.1109/IECON.2003.1280259 · DOI · Paper page
- 10.1109/TIE.2004.825284 · DOI · Paper page
- abrahamsen, 2000, fuse protection of igbts against rupture, Proc NORPIE, 64
- 10.1109/IAS.1997.629021 · doi:10.1109/ias.1997.629021
- iov, 2001, igbt fuses in voltage source converters, Proc PCIM, 267
- blaabjerg, 2002, fuse protection of igbt modules against explosions, J Power Electron, 2, 88
- iov, 2005, high-speed fuses in igbt based voltage source converters, Proc CIM, 164
- boyette, 2006, direct and indirect control of a doubly fed induction generator wind turbine including a storage unit, Proc 32th Annu Conf IEEE Ind Electron Soc, 2517
- 10.1109/TIE.2007.911196 · doi:10.1109/tie.2007.911196
- 10.1109/TIE.2007.898281 · DOI · Paper page
- 10.1016/j.renene.2006.12.002 · DOI · Paper page
- 10.1109/PES.2006.1709488 · doi:10.1109/pes.2006.1709488
- 10.1109/TIE.2006.878356 · DOI · Paper page
- 10.1109/TIE.2006.885137 · DOI
- 10.1109/TIE.2007.895076 · DOI · Paper page
- 10.1109/TIA.2002.800591 · DOI · Paper page
- 10.1049/ip-epa:20045099 · doi:10.1049/ip-epa:20045099
- 10.1109/TIE.2006.881997 · DOI · Paper page
- 10.1109/TIE.2006.874258 · DOI · Paper page
- 10.1109/TIE.2006.870658 · DOI · Paper page
- 10.1109/TIE.2007.898302 · DOI · Paper page
- 10.1109/TIE.2007.898304 · doi:10.1109/tie.2007.898304
- 10.1109/TIE.2007.898279 · doi:10.1109/tie.2007.898279
- 10.1109/TIE.2007.896129 · DOI
- 10.1109/TIE.2007.898305 · doi:10.1109/tie.2007.898305
- karimi, 2007, design and fpga in the loop prototyping methodology for power electronics system control, Proc IEEE Int Conf Electron Circuits and Syst, 701
- 10.1109/TIE.2007.892253 · doi:10.1109/tie.2007.892253
Cited by
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700
A Survey on Wind Turbine Condition Monitoring and Fault Diagnosis—Part I: Components and Subsystems
Qiao, W., & Lu, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2422112 · Cited by 533
A Digital Twin Approach for Fault Diagnosis in Distributed Photovoltaic Systems
Jain, P., Poon, J., Singh, J. P., Spanos, C., Sanders, S. R., & Panda, S. K. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2911594 · Cited by 462
Ji, B., Pickert, V., Cao, W., & Zahawi, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2251358 · Cited by 329
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Metadata
- Authors
- Karimi, S., Gaillard, A., Poure, P., & Saadate, S.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2008-12
- Volume
- 55
- Issue
- 12
- Pages
- 4299-4308
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2168306830
- Cited by
- 245
- References
- 0
- FWCI
- 13.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion Systems. https://app.cochat.ai/papers/10.1109/tie.2008.2005244
- The paper
- Karimi, S., Gaillard, A., Poure, P., & Saadate, S. (2008). FPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion Systems. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2008.2005244
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.