Self-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit

Qing-Chang Zhong, Phi-Long Nguyen, Zhenyu Ma, Wanxing Sheng·2014·IEEE Transactions on Power Electronics

Abstract

A synchronverter is an inverter that mimics synchronous generators, which offers a mechanism for power systems to control grid-connected renewable energy and facilitates smart grid integration. Similar to other grid-connected inverters, it needs a dedicated synchronization unit, e.g., a phase-locked loop (PLL), to provide the phase, frequency, and amplitude of the grid voltage as references. In this paper, a radical step is taken to improve the synchronverter as a self-synchronized synchronverter by removing the dedicated synchronization unit. It can automatically synchronize itself with the grid before connection and track the grid frequency after connection. This considerably improves the performance, reduces the complexity, and computational burden of the controller. All the functions of the original synchronverter, such as frequency and voltage regulation, real power, and reactive power control, are maintained. Both simulation and experimental results are presented to validate the control strategy. Experimental results have shown that the proposed control strategy can improve the performance of frequency tracking by more than 65%, the performance of real power control by 83%, and the performance of reactive power control by about 70%.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpel.2013.2258684

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cited by

Sorted by citations

Authors
Zhong, Q.-C., Nguyen, P.-L., Ma, Z., & Sheng, W.
Affiliations
  • University of Sheffield (GB)
  • Loughborough University (GB)
  • China Electric Power Research Institute (CN)
Venue
IEEE Transactions on Power Electronics
Published
2014-02
Volume
29
Issue
2
Pages
617-630
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2047617506
Cited by
1,026
References
0
Citations by year
2026: 29 · 2025: 75 · 2024: 81 · 2023: 89 · 2022: 114 · 2021: 107 · 2020: 113 · 2019: 130 · 2018: 90 · 2017: 72 · 2016: 59 · 2015: 43 · 2014: 20 · 2013: 4
FWCI
52.27
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Power Electronics (publishedVersion)
Funders
Engineering and Physical Sciences Research Council (EP/J001333/1, EP/J001333/2, EP/J01558X/1)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Islanding Detection in Power Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
Keywords
synchronverter, grid synchronization, grid-connected inverter, phase-locked loop elimination, frequency tracking, reactive power control, real power control, voltage and frequency regulation, renewable energy integration, smart grid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review