Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 226

The DOI matches its Crossref record.

Analysis Results of Output Power Loss Due to the Grid Voltage Rise in Grid-Connected Photovoltaic Power Generation Systems

Ueda, Y., Kurokawa, K., Tanabe, T., Kitamura, K., Sugihara, H.·2008·IEEE Transactions on Industrial Electronics

Abstract

This paper describes the connected photovoltaic (PV) power generation system's grid overvoltage protection function and summarizes the occurrence of the output power loss due to the grid voltage rise. Power injection from the PV system will raise the voltage at the power distribution line. A power conditioning subsystem (PCS) needs to regulate its output if the voltage becomes higher than the upper limit in order to avoid the overvoltage at the power grid. Thus, a PV system cannot generate electricity under the high grid voltage. There are 553 residential PV systems installed in Ota, Japan, for the demonstration research project of clustered PV systems. Measurement data of these 2.1-MW grid-connected PV systems are used for the analysis. Only the limited number of PV systems experienced a significant amount of output energy loss due to the high grid voltage in a particular day, whereas the other system's outputs also raise the grid voltage. The causes of this maldistribution of the output energy loss are the difference of the line impedance, the difference of the starting voltage of the PCS's grid overvoltage protection function, and the imbalance of the load in single-phase three-wire power distribution systems. The present control of the PCS successfully avoids the overvoltage on the grid but cannot share the loss.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2008.924447

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 226

Metadata

Authors
Ueda, Y., Kurokawa, K., Tanabe, T., Kitamura, K., & Sugihara, H.
Venue
IEEE Transactions on Industrial Electronics
Published
2008-07
Volume
55
Issue
7
Pages
2744-2751
ISSN
0278-0046 (ISSN-L)
OpenAlex
W2119986658
Cited by
226
References
0
FWCI
5.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis Results of Output Power Loss Due to the Grid Voltage Rise in Grid-Connected Photovoltaic Power Generation Systems. https://app.cochat.ai/papers/10.1109/tie.2008.924447
The paper
Ueda, Y., Kurokawa, K., Tanabe, T., Kitamura, K., & Sugihara, H. (2008). Analysis Results of Output Power Loss Due to the Grid Voltage Rise in Grid-Connected Photovoltaic Power Generation Systems. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2008.924447

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.