The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Distributed Volt/VAr Control by PV Inverters
Abstract
A major technical obstacle for rooftop photovoltaics (PV) integration into existing distribution systems is the voltage rise due to the reverse power flow from the distributed PV sources. This paper describes the implementation of a voltage control loop within PV inverters that maintains the voltage within acceptable bounds by absorbing or supplying reactive power. In principle, this can be considered to be a form of distributed Volt/VAr control, which is conventionally performed by coordinated control of capacitor banks and transformer tap changers. Comprehensive simulation studies on detailed feeder models are used to demonstrate that the proposed control scheme will mitigate voltage rises.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solar energy thermal processes
Klein, S. A. (1978) · Journal of the Franklin Institute · doi:10.1016/0016-0032(78)90125-4 · Cited by 1,125
Solar-Energy Thermal Processes
Duffie, J. A., Beckman, W. A., Winston, R., & Kreith, F. (1976) · Physics Today · doi:10.1063/1.3023429 · Cited by 1,101
Integration of Distributed Generation in the Power System
Bollen, M., & Hassan, F. (2011) · Wiley eBooks · doi:10.1002/9781118029039 · Cited by 740
Voltage rise: the big issue when connecting embedded generation to long 11 kV overhead lines
Masters, C. L. (2002) · Power Engineering Journal · doi:10.1049/pe:20020101 · Cited by 648
Distributed Reactive Power Generation Control for Voltage Rise Mitigation in Distribution Networks
Carvalho, P. M. S., Correia, P. F., & Ferreira, L. A. F. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.919203 · Cited by 607
Electric power distribution handbook
(2004) · Choice Reviews Online · doi:10.5860/choice.41-4699 · Cited by 514
Electric Power Distribution Handbook
Short, T. A. (2003) · CRC Press eBooks · doi:10.1201/9780203486504 · Cited by 407
Photovoltaic Generation Penetration Limits in Radial Distribution Systems
Shayani, R. A., & de Oliveira, M. A. G. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2077656 · Cited by 299
Ueda, Y., Kurokawa, K., Tanabe, T., Kitamura, K., & Sugihara, H. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924447 · Cited by 226
Novel Coordinated Voltage Control for Smart Distribution Networks With DG
Elkhatib, M. E., El-Shatshat, R., & Salama, M. M. A. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2162083 · Cited by 223
Cited by
Antoniadou-Plytaria, K. E., Kouveliotis-Lysikatos, I. N., Georgilakis, P. S., & Hatziargyriou, N. D. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2679238 · Cited by 545
Methods and strategies for overvoltage prevention in low voltage distribution systems with PV
Hashemi, S., & Østergaard, J. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0277 · Cited by 212
Optimal local volt/var control for photovoltaic inverters in active distribution networks
Sun, X., Qiu, J., & Zhao, J. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3080039 · Cited by 111
Postigo Marcos, F., Mateo Domingo, C., Gómez San Román, T., Palmintier, B., Hodge, B.-M., Krishnan, V., De Cuadra García, F., & Mather, B. (2017) · Energies · doi:10.3390/en10111896 · Cited by 106
Gebbran, D., Mhanna, S., Chapman, A. C., & Verbič, G. (2023) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3227635 · Cited by 38
Metadata
- Authors
- Jahangiri, P., & Aliprantis, D. C.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2013-08
- Volume
- 28
- Issue
- 3
- Pages
- 3429-3439
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2162732696
- Cited by
- 474
- References
- 19
- FWCI
- 16.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Distributed Volt/VAr Control by PV Inverters. https://app.cochat.ai/papers/10.1109/tpwrs.2013.2256375
- The paper
- Jahangiri, P., & Aliprantis, D. C. (2013). Distributed Volt/VAr Control by PV Inverters. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2013.2256375
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.