Abstract
Multilevel converters are an interesting alternative for high power drives, due to their good quality output signals. Despite their advantages, the large number of components required increases the fault probability. Among the multilevel topologies, the cascade multicell converter presents advantages when operating under internal fault conditions, due to its high modularity. Previous works proposed to compensate the unbalanced operation due to a fault by changing the canonical fundamental output phase shift to precalculated angles, depending on the fault condition. This solution assumes that, if the maximum output phase voltage on each leg is used, the maximum line-to-line voltage will be at a maximum as well. This paper shows how this assumption is not always valid and presents the optimum angles and modulation indexes that must be used in order to obtain the maximum balanced load voltages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charge balance control schemes for cascade multilevel converter in hybrid electric vehicles
Tolbert, L. M., Peng, F. Z., Cunnyngham, T., & Chiasson, J. N. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.803213 · Cited by 381 · cited 1×
“1(b)]; 2) a photovoltaic panel [4], [6]; 3) batteries [25]–[27].”
Background
Cited by
A Survey on Cascaded Multilevel Inverters
Malinowski, M., Gopakumar, K., Rodriguez, J., & Pérez, M. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030767 · Cited by 2,322
Survey on Fault-Tolerant Techniques for Power Electronic Converters
Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., & Krishnamoorthy, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304561 · Cited by 587
Leon, J. I., Vazquez, S., & Franquelo, L. G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2726583 · Cited by 481
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
Survey on Fault Operation on Multilevel Inverters
Lezana, P., Pou, J., Meynard, T. A., Rodriguez, J., Ceballos, S., & Richardeau, F. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032194 · Cited by 384
Self-citationA Postfault Strategy to Control the Modular Multilevel Converter Under Submodule Failure
Yang, Q., Qin, J., & Saeedifard, M. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2449875 · Cited by 69
Metadata
- Authors
- Lezana, P., & Ortiz, G.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-07
- Volume
- 56
- Issue
- 7
- Pages
- 2697-2703
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2106895166
- Cited by
- 219
- References
- 1
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.