Building-Environment Control With Wireless Sensor and Actuator Networks: Centralized Versus Distributed
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper considers joint problems of control and communication in wireless sensor and actuator networks (WSANs) for building-environment control systems. In traditional control systems, centralized control (CC) and distributed control (DC) are two major approaches. However, little work has been done in comparing the two approaches in joint problems of control and communication, particularly in WSANs serving as components of control loops. In this paper, we develop a CC scheme in which control decisions are made based on global information and a DC scheme which enables distributed actuators to make control decisions locally. We also develop methods that enable wireless communications among system devices compatible with the control strategies, and propose a method for reducing packet-loss rate. We compare the two schemes using simulations in many aspects. Simulation results show that the DC can achieve a comparable control performance of the CC, while the DC is more robust against packet loss and has lower computational complexity than the CC. Furthermore, the DC has shorter actuation latency than the CC under certain conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dounis, A. I., & Caraiscos, C. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2008.09.015 · Cited by 851
Cited by
Dong, H., Wang, Z., & Gao, H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2213553 · Cited by 372
Implementation of Hierarchical Control in DC Microgrids
Jin, C., Wang, P., Xiao, J., Tang, Y., & Choo, F. H. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2286563 · Cited by 368
Primary and secondary control in DC microgrids: a review
GAO, F., KANG, R., CAO, J., & YANG, T. (2019) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-018-0466-5 · Cited by 314
Chen, J., Cao, X., Cheng, P., Xiao, Y., & Sun, Y. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2043038 · Cited by 295
Self-citationLi, M., & Lin, H.-J. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2379586 · Cited by 290
(2017) · IEEE Control Systems · doi:10.1109/mcs.2016.2621479 · Cited by 160
Distributed Real-Time Anomaly Detection in Networked Industrial Sensing Systems
Chen, P.-Y., Yang, S., & McCann, J. A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2350451 · Cited by 148
“Industrial Sensing Systems: There exists a large body of research on networked sensing systems in industrial environments [5]–[7], such as building monitoring and control [8], smart water system monitoring [9], machine-condition monitoring and diagnostic [10], [11], and smart power grid systems [3].”
Background
Metadata
- Authors
- Cao, X., Chen, J., Xiao, Y., & Sun, Y.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-11
- Volume
- 57
- Issue
- 11
- Pages
- 3596-3605
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2151124278
- Cited by
- 184
- References
- 1
- FWCI
- 18.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.