Real-Time Simulation of a Wind Turbine Generator Coupled With a Battery Supercapacitor Energy Storage System
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Wind power generation studies of slow phenomena using a detailed model can be difficult to perform with a conventional offline simulation program. Due to the computational power and high-speed input and output, a real-time simulator is capable of conducting repetitive simulations of wind profiles in a short time with detailed models of critical components and allows testing of prototype controllers through hardware-in-the-loop (HIL). This paper discusses methods to overcome the challenges of real-time simulation of wind systems, characterized by their complexity and high-frequency switching. A hybrid flow-battery supercapacitor energy storage system (ESS), coupled in a wind turbine generator to smooth wind power, is studied by real-time HIL simulation. The prototype controller is embedded in one real-time simulator, while the rest of the system is implemented in another independent simulator. The simulation results of the detailed wind system model show that the hybrid ESS has a lower battery cost, higher battery longevity, and improved overall efficiency over its reference ESS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Supercapacitor Energy Storage for Wind Energy Applications
Abbey, C., & Joos, G. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.895768 · Cited by 837
Self-citationDesign, Analysis, and Real-Time Testing of a Controller for Multibus Microgrid System
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833456 · Cited by 723
Modeling the dynamic behavior of supercapacitors using impedance spectroscopy
Buller, S., Karden, E., Kok, D., & De Doncker, R. W. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.804762 · Cited by 401
Kinjo, T., Senjyu, T. S., Urasaki, N., & Fujita, H. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.853752 · Cited by 252
Li, W., & Joós, G. (2008) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2008.4592198 · Cited by 205
Self-citationA DSP-Based Remote Control Laboratory
Hercog, D., Gergic, B., Uran, S., & Jezernik, K. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907009 · Cited by 183
Real-time PC-based simulator of electric systems and drives
Abourida, S., Dufour, C., Bélanger, J., Murere, G., Lechevin, N., & Yu, B. (2003) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2002.989281 · Cited by 107
Gao, F., Blunier, B., Miraoui, A., & Moudni, A. E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2021177 · Cited by 106
Bouscayrol, A., Guillaud, X., Delarue, P., & Lemaire‐Semail, B. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2013251 · Cited by 103
Power Smoothing Using a Flywheel Driven by a Switched Reluctance Machine
Cárdenas, R., Pena, R. S., Perez, M., Clare, J., Asher, G., & Wheeler, P. W. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878325 · Cited by 100
Cited by
Review of energy system flexibility measures to enable high levels of variable renewable electricity
Lund, P. D., Lindgren, J., Mikkola, J., & Salpakari, J. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.01.057 · Cited by 1,700
Review of energy storage system for wind power integration support
Zhao, H., Wu, Q., Hu, S., Xu, H., & Rasmussen, C. N. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.04.103 · Cited by 1,134
Multiple Distributed Generator Placement in Primary Distribution Networks for Loss Reduction
Hung, D. Q., & Mithulananthan, N. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2112316 · Cited by 794
Supercapacitors for renewable energy applications: A review
Zhang, J., Gu, M., & Chen, X. (2023) · Micro and Nano Engineering · doi:10.1016/j.mne.2023.100229 · Cited by 483
Emergence of hybrid energy storage systems in renewable energy and transport applications – A review
Hemmati, R., & Saboori, H. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.029 · Cited by 423
Design and Analysis of Novel Control Strategy for Battery and Supercapacitor Storage System
Kollimalla, S. K., Mishra, M. K., & Narasamma, N. L. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2336896 · Cited by 398
Overview of wind power intermittency: Impacts, measurements, and mitigation solutions
Ren, G., Liu, J., Wan, J., Guo, Y., & Yu, D. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.06.098 · Cited by 352
Zhou, T., & Francois, B. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046580 · Cited by 339
Development of hybrid battery–supercapacitor energy storage for remote area renewable energy systems
Ma, T., Yang, H., & Lu, L. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.12.008 · Cited by 324
Chen, L.-R., Wu, S.-L., Shieh, D.-T., & Chen, T.-R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2186106 · Cited by 322
Recent Advances of Wind-Solar Hybrid Renewable Energy Systems for Power Generation: A Review
Roy, P., He, J., Zhao, T., & Singh, Y. V. (2022) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2022.3144093 · Cited by 312
Characteristics and Design of Power Hardware-in-the-Loop Simulations for Electrical Power Systems
Lauss, G., Faruque, M. O., Schoder, K., Dufour, C., Viehweider, A., & Langston, J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2464308 · Cited by 308
Supercapacitors: Electrical Characteristics, Modeling, Applications, and Future Trends
Berrueta, A., Ursua, A., Martin, I. S., Eftekhari, A., & Sanchis, P. (2019) · IEEE Access · doi:10.1109/access.2019.2908558 · Cited by 298
Power Smoothing of Large Solar PV Plant Using Hybrid Energy Storage
Wang, G., Ciobotaru, M., & Agelidis, V. G. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2305433 · Cited by 298
Analysis of Battery Lifetime Extension in a Small-Scale Wind-Energy System Using Supercapacitors
Gee, A. M., Robinson, F. V. P., & Dunn, R. W. (2013) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2012.2228195 · Cited by 298
Hierarchical Control of Hybrid Energy Storage System in DC Microgrids
Xiao, J., Wang, P., & Setyawan, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2400419 · Cited by 286
Hybrid energy storage systems and control strategies for stand-alone renewable energy power systems
Chong, L. W., Wong, Y. W., Rajkumar, R. K., Rajkumar, R. K., & Isa, D. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.07.059 · Cited by 279
A review of energy storage technologies for marine current energy systems
Zhou, Z., Benbouzid, M., Frédéric Charpentier, J., Scuiller, F., & Tang, T. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.10.006 · Cited by 278
A review on overall control of DC microgrids
Kumar, J., Agarwal, A., & Agarwal, V. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.11.013 · Cited by 257
Manandhar, U., Tummuru, N. R., Kollimalla, S. K., Ukil, A., Beng, G. H., & Chaudhari, K. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2750622 · Cited by 227
“PV is preferred in terms of sustainability and reliability, but its generation and stability are easily affected by intermittent operating conditions such as change in irradiance, temperature, humidity, and partial shadings effects [2], [3].”
BackgroundXu, D., Liu, J., Yan, X.-G., & Yan, W. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2767544 · Cited by 202
“In addition, the constraints and the restrictions of the smallrating HESS limited by its converter need to be considered [25].”
BackgroundLiu, Y.-H., Hsieh, C.-H., & Luo, Y.-F. (2011) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2010.2103077 · Cited by 193
Khalid, M. (2019) · Energies · doi:10.3390/en12234559 · Cited by 183
Comparison of three topologies and controls of a hybrid energy storage system for microgrids
Etxeberria, A., Vechiu, I., Camblong, H., & Vinassa, J.-M. (2012) · Energy Conversion and Management · doi:10.1016/j.enconman.2011.10.012 · Cited by 169
“The dynamic model of the VRB that has been used is presented in detail in [6, 13–15].”
Multilevel Energy Management System for Hybridization of Energy Storages in DC Microgrids
Xiao, J., Wang, P., & Setyawan, L. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2424983 · Cited by 160
“references for HRES and LRES accordingly in [22]–[25].”
BackgroundWali, S. B., Hannan, M. A., Reza, M. S., Ker, P. J., Begum, R. A., Rahman, M. S. A., & Mansor, M. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2021.102296 · Cited by 149
Metadata
- Authors
- Li, W., Joos, G., & Belanger, J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-04
- Volume
- 57
- Issue
- 4
- Pages
- 1137-1145
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2123108685
- Cited by
- 448
- References
- 12
- FWCI
- 42.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.