The DOI matches its Crossref record.
Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions
Open accessAbstract
This paper presents a new multiresonant frequency-adaptive synchronization method for grid-connected power converters that allows estimating not only the positive- and negative-sequence components of the power signal at the fundamental frequency but also other sequence components at other harmonic frequencies. The proposed system is called MSOGI-FLL since it is based on both a harmonic decoupling network consisting of multiple second-order generalized integrators (MSOGIs) and a frequency-locked loop (FLL), which makes the system frequency adaptive. In this paper, the MSOGI-FLL is analyzed for single- and three-phase applications, deducing some key expressions regarding its stability and tuning. Moreover, the performance of the MSOGI-FLL is evaluated by both simulations and experiments to show its capability for detecting different harmonic components in a highly polluted grid scenario.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Leon, J. I., Vazquez, S., & Franquelo, L. G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2726583 · Cited by 481
Camacho, A., Castilla, M., Miret, J., Borrell, A., & de Vicuna, L. G. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2347266 · Cited by 300
Steady-State Modeling of Modular Multilevel Converter Under Unbalanced Grid Conditions
Shi, X., Wang, Z., Liu, B., Li, Y., Tolbert, L. M., & Wang, F. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2629472 · Cited by 73
Change‐detection algorithm for short‐circuit fault detection in closed‐loop AC drives
Meinguet, F., Semail, E., Kestelyn, X., Mollet, Y., & Gyselinck, J. (2014) · IET Electric Power Applications · doi:10.1049/iet-epa.2012.0316 · Cited by 34
Metadata
- Authors
- Rodriguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., & Blaabjerg, F.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-01
- Volume
- 58
- Issue
- 1
- Pages
- 127-138
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2006246155
- Cited by
- 1,112
- References
- 0
- FWCI
- 66.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions. https://app.cochat.ai/papers/10.1109/tie.2010.2042420
- The paper
- Rodriguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., & Blaabjerg, F. (2011). Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2010.2042420
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.