Modeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Open accessAbstract
This paper develops and analyzes a parametric model for simulating healthy and faulty surface-mounted permanent magnet synchronous motors. It allows studying the effects of stator winding interturn short-circuit faults. A relevant feature of the developed model is that it deals with spatial harmonics due to a nonsinusoidal rotor permanent magnet configuration. Additionally, the proposed model is valid for studying the behavior of these machines running under nonstationary conditions, including load or speed variations. Stator current spectra obtained from simulations performed by applying the proposed model show a close similitude with experimental results, highlighting the potential of such a model to understand the effects of stator winding failures on the current spectrum and allowing it to carry out an automatic diagnosis of such faults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568
The detection of inter-turn short circuits in the stator windings of operating motors
Joksimovic, G. M., & Penman, J. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873216 · Cited by 471
Transient model for induction machines with stator winding turn faults
Tallam, R. M., Habetler, T. G., & Harley, R. G. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.1003411 · Cited by 428
Static-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors
Ebrahimi, B. M., Faiz, J., & Roshtkhari, M. J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029577 · Cited by 386
Henao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361
da Silva, A. M., Povinelli, R. J., & Demerdash, N. A. O. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.909060 · Cited by 266
Frosini, L., & Bassi, E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2026770 · Cited by 254
Ruiz, J.-R. R., Rosero, J. A., Espinosa, A. G., & Romeral, L. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2015942 · Cited by 231
Self-citationRosero, J. A., Romeral, L., Ortega, J. A., & Rosero, E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011580 · Cited by 214
Self-citationKim, K.-C., Lim, S.-B., Koo, D.-H., & Lee, J. (2006) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2006.879077 · Cited by 191
Rajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
Interior Permanent Magnet Motors With Reduced Torque Pulsation
Parsa, L., & Hao, L. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911953 · Cited by 128
Mohammed, O. A., Liu, Z., Liu, S., & Abed, N. Y. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2006.892301 · Cited by 97
Mohammed, O. A., Liu, S., & Liu, Z. (2006) · Digest of the Fifth Biennial IEEE Conference on Electromagnetic Field Computation · doi:10.1109/cefc-06.2006.1632949 · Cited by 59
Harmonics in rotating machines
Wakileh, G. J. (2003) · Electric Power Systems Research · doi:10.1016/s0378-7796(03)00069-5 · Cited by 57
Modelling and simulation of stator winding inter‐turn faults in permanent magnet synchronous motors
Farooq, J. A., Raminosoa, T., Djerdir, A., & Miraoui, A. (2008) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/03321640810878306 · Cited by 54
Stator short circuits detection in PMSM by means of Hilbert-Huang transform and energy calculation
Urresty, J., Riba, J., Romeral, L., Rosero, J., & Serna, J. (2009) · 2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2009.5292789 · Cited by 29 · cited 1×
“Additionally, other researchers have made efforts for identifying stator short-circuit faults from the acquired spectrum of the stator currents with no aim to generate a fault model [23]–[25].”
BackgroundSelf-citationDetection of Stator Short Circuits in PMSM by mean of joint Time-Frequency Analysis
Rosero, J., Cusidó, J., García, A., Romeral, L., & Ortega, J. A. (2007) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2007.4393131 · Cited by 17
Self-citationElectric motor faults diagnosis using artificial neural networks
Li, L., Mechefske, C. K., & Li, W. (2004) · Insight - Non-Destructive Testing and Condition Monitoring · doi:10.1784/insi.46.10.616.45210 · Cited by 13
Research works printed but not linked: 12
- 10.1016/j.epsr.2007.01.003 · doi:10.1016/j.epsr.2007.01.003
- 10.1109/TIE.2008.2004664 · doi:10.1109/tie.2008.2004664
- 10.1109/TEC.2008.918655 · doi:10.1109/tec.2008.918655
- 10.1049/iet-smt:20060030 · doi:10.1049/iet-smt:20060030
- 10.1109/TMAG.2009.2012785 · doi:10.1109/tmag.2009.2012785
- 10.1109/TIE.2009.2026232 · doi:10.1109/tie.2009.2026232
- 10.1109/TIE.2009.2014745 · doi:10.1109/tie.2009.2014745
- 10.1109/TIA.2008.2009653 · doi:10.1109/tia.2008.2009653
- mehala, 2007, Motor current signature analysis and its applications in induction motor fault diagnosis, Int J Syst Appl Eng Dev, 2, 29
- 10.1109/TIE.2009.2033487 · doi:10.1109/tie.2009.2033487
- 10.1109/TIE.2009.2033084 · doi:10.1109/tie.2009.2033084
- 10.1109/IEMDC.2007.382812 · doi:10.1109/iemdc.2007.382812
Cited by
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The models presented in the literature are described by differential equations, in a three-phase system A-B-C [42], [47], [83], [195], [196], [198], in a synchronous reference frame d-q for 3-phase motors [44], [72], [193], [194], [197], and also for multi-phase motors [213].”
MethodInfluentialEbrahimi, B. M., Javan Roshtkhari, M., Faiz, J., & Khatami, S. V. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2263777 · Cited by 271
Rare-earth-free propulsion motors for electric vehicles: A technology review
Riba, J.-R., López-Torres, C., Romeral, L., & Garcia, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.121 · Cited by 265
Self-citationDiscrete-Time Repetitive Control-Based ADRC for Current Loop Disturbances Suppression of PMSM Drives
Tian, M., Wang, B., Yu, Y., Dong, Q., & Xu, D. (2022) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3107635 · Cited by 255
Metadata
- Authors
- Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-05
- Volume
- 58
- Issue
- 5
- Pages
- 1576-1585
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2169582464
- Cited by
- 282
- References
- 20
- FWCI
- 10.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.