Simple Fault Diagnosis Based on Operating Characteristic of Brushless Direct-Current Motor Drives
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In this paper, a simple fault diagnosis scheme for brushless direct-current motor drives is proposed to maintain control performance under an open-circuit fault. The proposed scheme consists of a simple algorithm using the measured phase current information and detects open-circuit faults based on the operating characteristic of motors. It requires no additional sensors or electrical devices to detect open-circuit faults and can be embedded into the existing drive software as a subroutine without excessive computation effort. The feasibility of the proposed fault diagnosis algorithm is proven by simulation and experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906994 · Cited by 284
Fault-tolerant control in variable speed drives: a survey
Campos-Delgado, D. U., Espinoza-Trejo, D. R., & Palacios, E. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070203 · Cited by 228 · cited 1×
“In such applications, its control system or controller permits little tolerance for any accidents for precision and safety concerns [1], [2].”
Background
Cited by
A Data-Driven Fault Diagnosis Methodology in Three-Phase Inverters for PMSM Drive Systems
Cai, B., Zhao, Y., Liu, H., & Xie, M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2608842 · Cited by 471
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
“A simple method based on the operating characteristics of brushless direct current motor drives was presented in [26] where the diagnosis is accomplished without using additional sensors or electrical devices.”
MethodA New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298
Jung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
Model-Based Fault Detection and Identification for Switching Power Converters
Poon, J., Jain, P., Konstantakopoulos, I. C., Spanos, C., Panda, S. K., & Sanders, S. R. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2541342 · Cited by 257
Metadata
- Authors
- Park, B.-G., Lee, K.-J., Kim, R.-Y., Kim, T.-S., Ryu, J.-S., & Hyun, D.-S.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-05
- Volume
- 58
- Issue
- 5
- Pages
- 1586-1593
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2114273005
- Cited by
- 93
- References
- 4
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.