Induction Motor Diagnosis Based on a Transient Current Analytic Wavelet Transform via Frequency B-Splines
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, a new induction motor diagnosis methodology is proposed. The approach is based on obtaining a 2-D time-frequency plot representing the time-frequency evolution of the main components in an electrical machine transient current. The identification of characteristic patterns in the time-frequency plane caused by many of the fault-related components enables a reliable machine diagnosis. Unlike other continuous-wavelet-transform-based methods, this work uses frequency B-spline (FBS) wavelets. It is shown that these wavelets enable an efficient filtering in the region neighboring the main frequency, as well as enable a high level of detail in the time-frequency maps. As a consequence, the evolution of the most important current components is precisely traced. These characteristics make it easy to identify the patterns related to the fault components. The technique is applied to the experimental no-load start-up current of motors in a healthy state and with broken bars; the FBS capabilities are revealed. One of the novelties of this paper is the fact that the diagnosis is carried out via the identification not only of the traditional lower sideband harmonic but also of the upper sideband harmonic and four additional fault-related components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition
Cusid�Cusido, J., Romeral, L., Ortega, J. A., Rosero, J. A., & Garc�aGarcia Espinosa, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911960 · Cited by 512
Cited by
Convolutional Discriminative Feature Learning for Induction Motor Fault Diagnosis
Sun, W., Zhao, R., Yan, R., Shao, S., & Chen, X. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2672988 · Cited by 295
Leite, V. C. M. N., Borges da Silva, J. G., Veloso, G. F. C., Borges da Silva, L. E., Lambert-Torres, G., Bonaldi, E. L., & de Lacerda de Oliveira, L. E. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2345330 · Cited by 274
“form to detect faults in induction machines [25], [28], [29], [40].”
BackgroundSoualhi, A., Clerc, G., & Razik, H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2230598 · Cited by 264
Faiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
Metadata
- Authors
- Pons-Llinares, J., Antonino-Daviu, J. A., Riera-Guasp, M., Pineda-Sanchez, M., & Climente-Alarcon, V.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-05
- Volume
- 58
- Issue
- 5
- Pages
- 1530-1544
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2139783633
- Cited by
- 142
- References
- 1
- FWCI
- 23.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.