Demagnetization Modeling and Fault Diagnosing Techniques in Permanent Magnet Machines Under Stationary and Nonstationary Conditions: An Overview
The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
Permanent magnet (PM) machines are widely used in industrial processes due to their merits such as high power density and torque and low losses (high efficiency). These machines operate frequently under harsh conditions; therefore, they expose different types of faults. These faults can be diagnosed in initial stages using different techniques and prevent the faults' progress to catastrophic stages. One of the most important PM machine faults in terms of occurrence rate is demagnetization fault, whose causes can be heat, electrical, environmental or combinations. This may lead to efficiency drop, poor performance, and low reliability of the system. This paper attempts to review and summarize the demagnetization fault diagnosis methods in PM machines. First the fault generating factors and their impacts on the performance of the motor are discussed. Then, the recently developed techniques for demagnetization fault under stationary and nonstationary conditions in two separate sections are addressed. Presented methods are compared; their weaknesses and strengths are noted. Finally, suggestions for further research are proposed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the visibility of this symptom is strongly dependent on the configuration of the winding, and sometimes even in the case of demagnetization there are no harmonics or subharmonics other than those that occur in a healthy motor due to the natural existing asymmetries of the machine [19], [29], [84], [85].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [29]
In the citing paper
“This drawback can be eliminated by using the flux-based and BEMF methods which are capable of detecting both uniform and local demagnetization [15], [19], [29], [30], [32].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [29]
In the citing paper
“Moreover, as results from the dependence (3), other motor damages depending on the rotational speed, such as ITSCs (see (1)) and mechanical damages such as dynamic eccentricity, can be identified by the same frequencies in the stator currents [29], [32].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [29]
In the citing paper
“The use of BEMF analysis is characterized by the lack of robustness to temperature changes of PMs [3], but the method is simple to implement [29], [95].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [29]
Citations
Cites
A review on empirical mode decomposition in fault diagnosis of rotating machinery
Lei, Y., Lin, J., He, Z., & Zuo, M. J. (2013) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2012.09.015 · Cited by 1,886
Current Signature Analysis to Detect Induction Motor Faults
Thomson, W. T., & Fenger, M. (2001) · IEEE Industry Applications Magazine · doi:10.1109/2943.930988 · Cited by 1,139
Permanent Magnet Synchronous and Brushless DC Motor Drives
Krishnan, R. (2017) · CRC Press eBooks · doi:10.1201/9781420014235 · Cited by 1,114
Permanent magnet motor technology : design and applications
Gieras, J. F., & Wing, M. (1996) · Thammasat University Digital Collections · Cited by 746
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Methods of Motor Current Signature Analysis
Kliman, G. B., & Stein, J. (1992) · Electric Machines & Power Systems · doi:10.1080/07313569208909609 · Cited by 330
Da, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303
Detecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274
Ruoho, S., Kolehmainen, J., Ikaheimo, J., & Arkkio, A. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2033592 · Cited by 264
Espinosa, A. G., Rosero, J. A., Cusido, J., Romeral, L., & Ortega, J. A. (2010) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2009.2037922 · Cited by 243
Research works printed but not linked: 1
- miller, 1989, Permanent Magnet and Reluctance Motor Drives
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The PM demagnetization can be uniform over all poles or partial over certain region or poles [15], [18], [29], [32].”
BackgroundMethodInfluentialChoi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Hang, J., Zhang, J., Xia, M., Ding, S., & Hua, W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2953269 · Cited by 150
Yepes, A. G., López, Ó., González‐Prieto, I., Duran, M. J., & Doval‐Gandoy, J. (2022) · Machines · doi:10.3390/machines10030208 · Cited by 150
In-Wheel Motor Vibration Control for Distributed-Driven Electric Vehicles: A Review
Zhao, Z. X., Taghavifar, H., Du, H., Qin, Y., Dong, M., & Gu, L. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3074970 · Cited by 129
Metadata
- Authors
- Faiz, J., & Mazaheri-Tehrani, E.
- Affiliations
- University of Tehran (IR)
- ORCID
- Faiz, Jawad
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2017-05
- Volume
- 53
- Issue
- 3
- Pages
- 2772-2785
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2519918482
- Cited by
- 207
- References
- 72
- Citations by year
- 2026: 10 · 2025: 30 · 2024: 32 · 2023: 39 · 2022: 31 · 2021: 18 · 2020: 17 · 2019: 19 · 2018: 8 · 2017: 3
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet machines, demagnetization fault, fault diagnosis, non-stationary conditions, stationary conditions, motor performance degradation, reliability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Demagnetization Modeling and Fault Diagnosing Techniques in Permanent Magnet Machines Under Stationary and Nonstationary Conditions: An Overview. https://app.cochat.ai/papers/10.1109/tia.2016.2608950
- The paper
- Faiz, J., & Mazaheri-Tehrani, E. (2017). Demagnetization Modeling and Fault Diagnosing Techniques in Permanent Magnet Machines Under Stationary and Nonstationary Conditions: An Overview. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2016.2608950
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.