The DOI matches its Crossref record.
Optimal Operation of Distribution Feeders in Smart Grids
Abstract
This paper presents a generic and comprehensive distribution optimal power flow (DOPF) model that can be used by local distribution companies (LDCs) to integrate their distribution system feeders into a Smart Grid. The proposed three-phase DOPF framework incorporates detailed modeling of distribution system components and considers various operating objectives. Phase specific and voltage dependent modeling of customer loads in the three-phase DOPF model allows LDC operators to determine realistic operating strategies that can improve the overall feeder efficiency. The proposed distribution system operation objective is based on the minimization of the energy drawn from the substation while seeking to minimize the number of switching operations of load tap changers and capacitors. A novel method for solving the three-phase DOPF model by transforming the mixed-integer nonlinear programming problem to a nonlinear programming problem is proposed which reduces the computational burden and facilitates its practical implementation and application. Two practical case studies, including a real distribution feeder test case, are presented to demonstrate the features of the proposed methodology. The results illustrate the benefits of the proposed DOPF in terms of reducing energy losses while limiting the number of switching operations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey on smart grid technologies and applications
Dileep, G. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.08.092 · Cited by 1,020
OPF-Based CVR Operation in PV-Rich MV-LV Distribution Networks
Gutierrez-Lagos, L., & Ochoa, L. F. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2894795 · Cited by 67
Marra, F., Fawzy, Y. T., Bulo, T., & Blazic, B. (2012) · 2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe) · doi:10.1109/isgteurope.2012.6465690 · Cited by 53
Gebbran, D., Mhanna, S., Chapman, A. C., & Verbič, G. (2023) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3227635 · Cited by 38
A comprehensive multi-period optimal power flow framework for smart LV networks
Avramidis, I. I., Capitanescu, F., & Deconinck, G. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3040502 · Cited by 19
Metadata
- Authors
- Paudyal, S., Canizares, C. A., & Bhattacharya, K.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-10
- Volume
- 58
- Issue
- 10
- Pages
- 4495-4503
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2160935860
- Cited by
- 311
- References
- 0
- FWCI
- 22.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Operation of Distribution Feeders in Smart Grids. https://app.cochat.ai/papers/10.1109/tie.2011.2112314
- The paper
- Paudyal, S., Canizares, C. A., & Bhattacharya, K. (2011). Optimal Operation of Distribution Feeders in Smart Grids. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2011.2112314
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.