Switched Z-Source Isolated Bidirectional DC–DC Converter and Its Phase-Shifting Shoot-Through Bivariate Coordinated Control Strategy
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents a novel switched Z-source isolated bidirectional dc-dc converter. The converter employs two unique switched impedance networks to couple the main circuit and the power source and load. Compared with the traditional isolated bidirectional dc-dc converter, the proposed converter has a wider regulation range of voltage. In addition, due to the fully symmetrical circuit configuration, there is neither a high-voltage side nor a low-voltage side in the circuit structure, and the sources connected to the dc side of each H-bridge can be both voltage sources and current sources. At the same time, the converter can bear shoot-through phenomenon in H-bridges, so it has high reliability. The topology configuration and operating principle of this converter are analyzed, and a unique phase-shifting shoot-through bivariate coordinated control strategy is designed and implemented. Both simulation and experimental results verify the analytical results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new ZVS bidirectional DC-DC converter for fuel cell and battery application
Peng, F. Z., Li, H., Su, G.-J., & Lawler, J. S. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820550 · Cited by 782 · cited 2×
“In addition, the isolated BDC (IBDC) is needed to provide absolute electrical isolation between the primary side and the secondary side for protecting the equipment and operators [8], which is particularly important for military and other missioncritical applications [8]–[15].”
BackgroundKrismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 1×
“Moreover, the corresponding phase shift changes the voltage across the transformer’s leakage inductance to manipulate the power flow direction and magnitude [11]–[15].”
Background
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Self-citationImpedance-Source Networks for Electric Power Conversion Part I: A Topological Review
Siwakoti, Y. P., Peng, F. Z., Blaabjerg, F., Loh, P. C., & Town, G. E. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2313746 · Cited by 702
Topologies and Control Schemes of Bidirectional DC–DC Power Converters: An Overview
Gorji, S. A., Sahebi, H. G., Ektesabi, M., & Rad, A. B. (2019) · IEEE Access · doi:10.1109/access.2019.2937239 · Cited by 439
Zhao, B., Song, Q., & Liu, W. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2210563 · Cited by 325
Self-citationA review of galvanically isolated impedance-source DC-DC converters
Chub, A., Vinnikov, D., Blaabjerg, F., & Peng, F. Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2453128 · Cited by 243
Metadata
- Authors
- Zhao, B., Yu, Q., Leng, Z., & Chen, X.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2012-12
- Volume
- 59
- Issue
- 12
- Pages
- 4657-4670
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2147425211
- Cited by
- 68
- References
- 2
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Switched Z-Source Isolated Bidirectional DC–DC Converter and Its Phase-Shifting Shoot-Through Bivariate Coordinated Control Strategy. https://app.cochat.ai/papers/10.1109/tie.2011.2181136
- The paper
- Zhao, B., Yu, Q., Leng, Z., & Chen, X. (2012). Switched Z-Source Isolated Bidirectional DC–DC Converter and Its Phase-Shifting Shoot-Through Bivariate Coordinated Control Strategy. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2011.2181136
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.