The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Efficiency Characterization and Optimization of Isolated Bidirectional DC–DC Converter Based on Dual-Phase-Shift Control for DC Distribution Application
Abstract
Compared to the traditional single-phase-shift control, dual-phase-shift (DPS) control can greatly improve the performance of the isolated bidirectional dc–dc converter (IBDC). This paper gives a detailed switching characteristic analysis of IBDC under DPS control, establishes a power loss model to predict the dissipated power for each power component, and analyzes the efficiency-optimized characteristic across the whole range. On this basis, an efficiency-optimized switching strategy is proposed and the corresponding control scheme is designed and implemented. At last, an experimental prototype was implemented to verify the feasibility of the proposed switching strategy and correctness of the theoretical analysis. The experimental results show that the proposed method can minimize the power loss and maximize the system efficiency, and these performances are particularly effective for operation conditions with high voltage conversion ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bai, H., & Mi, C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005103 · Cited by 1,121
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932
Self-citationHigh-Performance Adaptive Perturb and Observe MPPT Technique for Photovoltaic-Based Microgrids
Abdelsalam, A. K., Massoud, A. M., Ahmed, S., & Enjeti, P. N. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106221 · Cited by 879
Control Strategy for Flexible Microgrid Based on Parallel Line-Interactive UPS Systems
Guerrero, J. M., Vasquez, J. C., Matas, J., Castilla, M., & de Vicuna, L. G. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009274 · Cited by 788
A Bidirectional DC–DC Converter for an Energy Storage System With Galvanic Isolation
Inoue, S., & Akagi, H. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.909248 · Cited by 780
Efficiency-Optimized High-Current Dual Active Bridge Converter for Automotive Applications
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2112312 · Cited by 747
Closed Form Solution for Minimum Conduction Loss Modulation of DAB Converters
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2157976 · Cited by 635
Pwm control of dual active bridge: Comprehensive analysis and experimental verification
Jain, A. K., & Ayyanar, R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2070519 · Cited by 567
Switching Control Strategy to Minimize Dual Active Bridge Converter Losses
Oggier, G. G., GarcÍa, G. O., & Oliva, A. R. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2020902 · Cited by 514
Oggier, G. G., Garcia, G. O., & Oliva, A. R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2072966 · Cited by 498
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Self-citationHou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
Huang, J., Wang, Y., Li, Z., & Lei, W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2543182 · Cited by 501
Tong, A., Hang, L., Li, G., Jiang, X., & Gao, S. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2692276 · Cited by 455
Topologies and Control Schemes of Bidirectional DC–DC Power Converters: An Overview
Gorji, S. A., Sahebi, H. G., Ektesabi, M., & Rad, A. B. (2019) · IEEE Access · doi:10.1109/access.2019.2937239 · Cited by 439
Metadata
- Authors
- Zhao, B., Song, Q., & Liu, W.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-04
- Volume
- 28
- Issue
- 4
- Pages
- 1711-1727
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2093805979
- Cited by
- 325
- References
- 28
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficiency Characterization and Optimization of Isolated Bidirectional DC–DC Converter Based on Dual-Phase-Shift Control for DC Distribution Application. https://app.cochat.ai/papers/10.1109/tpel.2012.2210563
- The paper
- Zhao, B., Song, Q., & Liu, W. (2013). Efficiency Characterization and Optimization of Isolated Bidirectional DC–DC Converter Based on Dual-Phase-Shift Control for DC Distribution Application. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2012.2210563
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.