Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 339

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault

Open access
Camacho, Antonio, Castilla, Miguel, Miret, Jaume, Vasquez, Juan C., Alarcon-Gallo, Eduardo·2013·IEEE Transactions on Industrial Electronics

Abstract

Ancillary services for distributed generation (DG) systems become a challenging issue to smartly integrate renewable-energy sources into the grid. Voltage control is one of these ancillary services which can ride through and support the voltage under grid faults. Grid codes from the transmission system operators describe the behavior of the energy source, regulating voltage limits and reactive power injection to remain connected and support the grid under fault. On the basis that different kinds of voltage sags require different voltage support strategies, a flexible control scheme for three-phase grid-connected inverters is proposed. In three-phase balanced voltage sags, the inverter should inject reactive power in order to raise the voltage in all phases. In one- or two-phase faults, the main concern of the DG inverter is to equalize voltages by reducing the negative symmetric sequence and clear the phase jump. Due to system limitations, a balance between these two extreme policies is mandatory. Thus, over- and undervoltage can be avoided, and the proposed control scheme prevents disconnection while achieving the desired voltage support service. The main contribution of this work is the introduction of a control algorithm for reference current generation that provides flexible voltage support under grid faults. Two different voltage sags have been experimentally tested to illustrate the behavior of the proposed voltage support control scheme.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2012.2185016

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 339

Metadata

Authors
Camacho, A., Castilla, M., Miret, J., Vasquez, J. C., & Alarcon-Gallo, E.
Venue
IEEE Transactions on Industrial Electronics
Published
2013-04
Volume
60
Issue
4
Pages
1429-1441
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W1973313694
Cited by
339
References
1
FWCI
35.24
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault. https://app.cochat.ai/papers/10.1109/tie.2012.2185016
The paper
Camacho, A., Castilla, M., Miret, J., Vasquez, J. C., & Alarcon-Gallo, E. (2013). Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2012.2185016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.