The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hybrid Voltage and Current Control Approach for DG-Grid Interfacing Converters With $LCL$ filters
Abstract
This paper presents a hybrid voltage and current control method to improve the performance of interfacing converters in distributed generation (DG) units. In general, current-controlled methods have been widely adopted in grid-connected converters nowadays. Nevertheless, in an islanded system, the voltage control of DG units is desired to provide direct voltage support to the loads. Due to the absence of closed-loop line current controller, the voltage control scheme can hardly regulate the DG unit's line current harmonics. Furthermore, if not addressed properly, the transfer between the grid-connected operation and autonomous islanding operation will introduce nontrivial transient currents. To overcome the drawbacks of voltage- and current-controlled DG units, this paper develops a hybrid voltage and current control method (HCM). The proposed method allows the coordinated closed-loop control of the DG unit fundamental voltage and line harmonic currents. With the HCM, local harmonic loads of the DG unit can even be compensated without using harmonic current extraction. In addition, the HCM guarantees smooth transition during the grid-connected/islanding operation mode transfer. Simulated and experimental results are provided to verify the feasibility of the proposed approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Cited by
Overview of Power Management Strategies of Hybrid AC/DC Microgrid
Nejabatkhah, F., & Li, Y. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2384999 · Cited by 986
Self-citationWu, W., Liu, Y., He, Y., Chung, H. S.-H., Liserre, M., & Blaabjerg, F. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2714143 · Cited by 397
Stability and Control Aspects of Microgrid Architectures–A Comprehensive Review
Ahmed, M., Meegahapola, L., Vahidnia, A., & Datta, M. (2020) · IEEE Access · doi:10.1109/access.2020.3014977 · Cited by 326
Bajaj, M., & Singh, A. K. (2020) · International Journal of Energy Research · doi:10.1002/er.4847 · Cited by 324
Power Quality Control of Smart Hybrid AC/DC Microgrids: An Overview
Nejabatkhah, F., Li, Y. W., & Tian, H. (2019) · IEEE Access · doi:10.1109/access.2019.2912376 · Cited by 258
Self-citation
Metadata
- Authors
- He, J., & Li, Y. W.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-05
- Volume
- 60
- Issue
- 5
- Pages
- 1797-1809
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W1976265497
- Cited by
- 180
- References
- 1
- FWCI
- 15.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hybrid Voltage and Current Control Approach for DG-Grid Interfacing Converters With $LCL$ filters. https://app.cochat.ai/papers/10.1109/tie.2012.2190374
- The paper
- He, J., & Li, Y. W. (2013). Hybrid Voltage and Current Control Approach for DG-Grid Interfacing Converters With $LCL$ filters. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2012.2190374
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.