The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
A Deterministic Particle Swarm Optimization Maximum Power Point Tracker for Photovoltaic System under Partial Shading Condition
Abstract
This paper proposes a deterministic particle swarm optimization to improve the maximum power point tracking (MPPT) capability for photovoltaic system under partial shading condition. The main idea is to remove the random number in the accelerations factor of the conventional PSO velocity equation. Additionally, the maximum change in velocity is restricted to a particular value, which is determined based on the critical study ofP-Vcharacteristics during partial shading. Advantages of the method include: 1) consistent solution is achieved despite a small number of particles, 2) only one parameter, i.e., the inertia weight, needs to be tuned, and 3) the MPPT structure is much simpler compared to the conventional PSO. To evaluate the idea, the algorithm is implemented on a buck-boost converter and compared to the conventional hill climbing (HC) MPPT method. Simulation results indicate that the proposed method outperforms the HC method in terms of global peak tracking speed and accuracy under various partial shading conditions. Furthermore, it is tested using the measured data of a tropical cloudy day, which includes rapid movement of the passing clouds and partial shading. Despite the wide fluctuations in array power, the average efficiency for the 10-h test profile reaches 99.5%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new optimizer using particle swarm theory
Eberhart, R., & Kennedy, J. (2002) · MHS'95. Proceedings of the Sixth International Symposium on Micro Machine and Human Science · doi:10.1109/mhs.1995.494215 · Cited by 16,067
Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques
Esram, T., & Chapman, P. L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874230 · Cited by 5,425
Optimization of Perturb and Observe Maximum Power Point Tracking Method
Femia, N., Petrone, G., Spagnuolo, G., & Vitelli, M. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.850975 · Cited by 3,002
Review of Nonisolated High-Step-Up DC/DC Converters in Photovoltaic Grid-Connected Applications
Li, W., & He, X. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049715 · Cited by 1,423
Simple, fast and accurate two-diode model for photovoltaic modules
Ishaque, K., Salam, Z., & Taheri, H. (2011) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2010.09.023 · Cited by 687
Self-citationHighly Efficient Single-Phase Transformerless Inverters for Grid-Connected Photovoltaic Systems
Araujo, S. V., Zacharias, P., & Mallwitz, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2037654 · Cited by 636
Alajmi, B. N., Ahmed, K. H., Finney, S. J., & Williams, B. W. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2090903 · Cited by 635
Kadri, R., Gaubert, J.-P., & Champenois, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2044733 · Cited by 536
Single-Phase Seven-Level Grid-Connected Inverter for Photovoltaic System
Rahim, N. A., Chaniago, K., & Selvaraj, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2064278 · Cited by 438
A Multilevel Inverter for Photovoltaic Systems With Fuzzy Logic Control
Cecati, C., Ciancetta, F., & Siano, P. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2044119 · Cited by 424
Ishaque, K., & Salam, Z. (2011) · Solar Energy · doi:10.1016/j.solener.2011.06.025 · Cited by 419
Self-citationPredictive & Adaptive MPPT Perturb and Observe Method
Femia, N., Granozio, D., Petrone, G., Spagnuolo, G., & Vitelli, M. (2007) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.2007.4383584 · Cited by 406
A Maximum Power Point Tracking Technique for Partially Shaded Photovoltaic Systems in Microgrids
Alajmi, B. N., Ahmed, K. H., Finney, S. J., & Williams, B. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2168796 · Cited by 404
Ishaque, K., Salam, Z., Taheri, H., & Shamsudin, A. (2011) · Solar Energy · doi:10.1016/j.solener.2011.04.015 · Cited by 211
Self-citationSoft-Switching Converter With HF Transformer for Grid-Connected Photovoltaic Systems
Cacciato, M., Consoli, A., Attanasio, R., & Gennaro, F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032201 · Cited by 129
Miyatake, M., Toriumi, F., Endo, T., & Fujii, N. (2007) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417640 · Cited by 111
Phimmasone, V., Kondo, Y., Kamejima, T., & Miyatake, M. (2010) · International Conference on Electrical Machines and Systems (ICEMS) · Cited by 54
Cited by
A social learning particle swarm optimization algorithm for scalable optimization
Cheng, R., & Jin, Y. (2015) · Information Sciences · doi:10.1016/j.ins.2014.08.039 · Cited by 747
Ishaque, K., & Salam, Z. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.11.032 · Cited by 600
Self-citationA comprehensive review on solar PV maximum power point tracking techniques
Ram, J. P., Babu, T. S., & Rajasekar, N. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.09.076 · Cited by 511
Li, H., Yang, D., Su, W., Lu, J., & Yu, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2829668 · Cited by 508
Grid-Connected Photovoltaic Generation Plants: Components and Operation
Romero-Cadaval, E., Spagnuolo, G., Franquelo, L. G., Ramos-Paja, C. A., Suntio, T., & Xiao, W. M. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2264540 · Cited by 449
Metadata
- Authors
- Ishaque, K., & Salam, Z.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2012
- Pages
- 1-1
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2051900843
- Cited by
- 601
- References
- 17
- FWCI
- 14.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.