The DOI matches its Crossref record.
Grid-Connected Photovoltaic Generation Plants: Components and Operation
Open accessAbstract
The main design objective of photovoltaic (PV) systems has been, for a long time, to extract the maximum power from the PV array and inject it into the ac grid. Therefore, the maximum power point tracking (MPPT) of a uniformly irradiated PV array and the maximization of the conversion efficiency have been the main design issues. However, when the PV plant is connected to the grid, special attention has to be paid to the reliability of the system, the power quality, and the implementation of protection and grid synchronization functions. Modern power plants are required to maximize their energy production, requiring suitable control strategies to solve the problems related to the partial shading phenomena and different orientation of the PV modules toward the sun. Moreover, the new policy concerning the injection of reactive power into the grid makes the development of suitable topologies and control algorithms mandatory. A general view of actual solutions for applications of the PV energy systems is presented. This article covers several important issues, including the most reliable models used for simulation, which are useful in the design of control systems, and the MPPT function, particularly in distributed ?applications. The main topologies used in the PV power processing system and, finally, grid connection aspects are discussed, with emphasis on synchronization, protections, and integration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kouro, S., Leon, J. I., Vinnikov, D., & Franquelo, L. G. (2015) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2014.2376976 · Cited by 1,197
Self-citationLeon, J. I., Vazquez, S., & Franquelo, L. G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2726583 · Cited by 481
Self-citationHu, J., Wang, Z., Liu, S., & Gao, H. (2016) · Automatica · doi:10.1016/j.automatica.2015.11.008 · Cited by 388
Solar Photovoltaic and Thermal Energy Systems: Current Technology and Future Trends
Malinowski, M., Leon, J. I., & Abu-Rub, H. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2690343 · Cited by 213
Anurag, A., Yang, Y., & Blaabjerg, F. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2428432 · Cited by 153
Metadata
- Authors
- Romero-Cadaval, E., Spagnuolo, G., Franquelo, L. G., Ramos-Paja, C. A., Suntio, T., & Xiao, W. M.
- Venue
- IEEE Industrial Electronics Magazine
- Published
- 2013-09
- Volume
- 7
- Issue
- 3
- Pages
- 6-20
- ISSN
- 1932-4529 (ISSN-L)
- OpenAlex
- W2079974359
- Cited by
- 449
- References
- 0
- FWCI
- 16.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Grid-Connected Photovoltaic Generation Plants: Components and Operation. https://app.cochat.ai/papers/10.1109/mie.2013.2264540
- The paper
- Romero-Cadaval, E., Spagnuolo, G., Franquelo, L. G., Ramos-Paja, C. A., Suntio, T., & Xiao, W. M. (2013). Grid-Connected Photovoltaic Generation Plants: Components and Operation. IEEE Industrial Electronics Magazine. https://doi.org/10.1109/mie.2013.2264540
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.