The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
An Energy-Based Controller for HVDC Modular Multilevel Converter in Decoupled Double Synchronous Reference Frame for Voltage Oscillation Reduction
Abstract
This paper consists of the presentation of a regulation strategy capable of controlling the energy stored in the modular multilevel converter (MMC) in an HVDC configuration. This is achieved by regulating the positive, negative, and zero sequences indqocoordinates of the differential current using two rotating reference frames: at once and at twice the fundamental grid frequency value. The active and reactive negative sequence components of the differential current at twice the fundamental frequency are used to eliminate the oscillations of the three-phased leg energy, reducing significantly the capacitor voltage oscillations, while the zero-sequence component is used to regulate the total energy stored at a given reference. Meanwhile, active and reactive positive sequence components of the circulating current are used for eliminating the average energy difference between the upper and lower arms in a three-phase MMC. In order to decouple efficiently the differential current components, the decoupled-double-synchronous-reference-frame current control strategy is used. Finally, simulation results validate the performance of the MMC in an HVDC configuration with the proposed control. Control equations are demonstrated, and cross-coupled leg-energy terms are introduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216
Control and Experiment of Pulsewidth-Modulated Modular Multilevel Converters
Hagiwara, M., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014236 · Cited by 1,565
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Decoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
Dynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188
Modulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934
Overview of Multi-MW Wind Turbines and Wind Parks
Liserre, M., Cardenas, R., Molinas, M., & Rodriguez, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2103910 · Cited by 876
Self-citationOn dynamics and voltage control of the Modular Multilevel Converter
Antonopoulos, A., Ängquist, L., & Nee, H. (2009) · European Conference on Power Electronics and Applications · Cited by 831
New transformerless, scalable Modular Multilevel Converters for HVDC-transmission
Allebrod, S., Hamerski, R., & Marquardt, R. (2008) · 2008 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2008.4591920 · Cited by 785
Cited by
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
Analysis of the Phase-Shifted Carrier Modulation for Modular Multilevel Converters
Li, B., Yang, R., Xu, D., Wang, G., Wang, W., & Xu, D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2299802 · Cited by 403
Zhang, M., Huang, L., Yao, W., & Lu, Z. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2269140 · Cited by 292
Frequency Domain Stability Analysis of MMC-Based HVdc for Wind Farm Integration
Lyu, J., Cai, X., & Molinas, M. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2498182 · Cited by 267
Self-citationFault Detection and Localization Method for Modular Multilevel Converters
Deng, F., Chen, Z., Khan, M. R., & Zhu, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2348194 · Cited by 266
Metadata
- Authors
- Bergna, G., Berne, E., Egrot, P., Lefranc, P., Arzande, A., Vannier, J.-C., & Molinas, M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-06
- Volume
- 60
- Issue
- 6
- Pages
- 2360-2371
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2136509165
- Cited by
- 267
- References
- 24
- FWCI
- 17.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Energy-Based Controller for HVDC Modular Multilevel Converter in Decoupled Double Synchronous Reference Frame for Voltage Oscillation Reduction. https://app.cochat.ai/papers/10.1109/tie.2012.2225397
- The paper
- Bergna, G., Berne, E., Egrot, P., Lefranc, P., Arzande, A., Vannier, J.-C., & Molinas, M. (2013). An Energy-Based Controller for HVDC Modular Multilevel Converter in Decoupled Double Synchronous Reference Frame for Voltage Oscillation Reduction. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2012.2225397
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.