LVRT Capability of DFIG-Based WECS Under Asymmetrical Grid Fault Condition
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, the low-voltage ride-through (LVRT) capability of the doubly fed induction generator (DFIG)-based wind energy conversion system in the asymmetrical grid fault situation is analyzed, and the control scheme for the system is proposed to follow the requirements defined by the grid codes. As analyzed in the paper, the control efforts of the negative-sequence current are much higher than that of the positive-sequence current for the DFIG. As a result, the control capability of the DFIG restrained by the dc-link voltage will degenerate for the fault type with higher negative-sequence voltage component and 2φ fault turns out to be the most serious scenario for the LVRT problem. When the fault location is close to the grid connection point, the DFIG may be out of control resulting in non-ride-through zones. In the worst circumstance when LVRT can succeed, the maximal positive-sequence reactive current supplied by the DFIG is around 0.4 pu, which coordinates with the present grid code. Increasing the power rating of the rotor-side converter can improve the LVRT capability of the DFIG but induce additional costs. Based on the analysis, an LVRT scheme for the DFIG is also proposed by taking account of the code requirements and the control capability of the converters. As verified by the simulation and experimental results, the scheme can promise the DFIG to supply the defined positive-sequence reactive current to support the power grid and mitigate the oscillations in the generator torque and dc-link voltage, which improves the reliability of the wind farm and the power system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips
LÓpez, J., Sanchis, P., Roboam, X., & Marroyo, L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.878241 · Cited by 550 · cited 3×
“An abrupt voltage drop can result in overvoltages or overcurrents in the rotor windings which may destroy the rotorside converter (RSC) if no protection measures are employed [3].”
BackgroundMethodInfluential
Cited by
Fast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
Zheng, L., Geng, H., & Yang, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585078 · Cited by 83
Self-citation
Metadata
- Authors
- Geng, H., Liu, C., & Yang, G.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-06
- Volume
- 60
- Issue
- 6
- Pages
- 2495-2509
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2055596962
- Cited by
- 231
- References
- 1
- FWCI
- 12.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.