CoChat

Analysis and Implementation of a Single-Stage Flyback PV Microinverter With Soft Switching

Sukesh, Nikhil, Pahlevaninezhad, Majid, Jain, Praveen K. · 2014 · IEEE Transactions on Industrial Electronics
Cited by 188

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

This paper presents a novel zero-voltage switching (ZVS) approach to a grid-connected single-stage flyback inverter. The soft-switching of the primary switch is achieved by allowing negative current from the grid side through bidirectional switches placed on the secondary side of the transformer. Basically, the negative current discharges the metal-oxide-semiconductor field-effect transistor's output capacitor, thereby allowing turn on of the primary switch under zero voltage. To optimize the amount of reactive current required to achieve ZVS, a variable-frequency control scheme is implemented over the line cycle. In addition, the bidirectional switches on the secondary side of the transformer have ZVS during the turn- on times. Therefore, the switching losses of the bidirectional switches are negligible. A 250-W prototype has been implemented to validate the proposed scheme. Experimental results confirm the feasibility and superior performance of the converter compared with the conventional flyback inverter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2013.2263778

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Sukesh, N., Pahlevaninezhad, M., & Jain, P. K.
Venue
IEEE Transactions on Industrial Electronics
Published
2014-04
Volume
61
Issue
4
Pages
1819-1833
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W2008530066
Cited by
188
References
10
FWCI
11.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.