The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Active Disturbance Rejection Control for a Flywheel Energy Storage System
Abstract
This paper presents the application of the Active Disturbance Rejection Control Technique (ADRCT) to improve the performance of a Flywheel Energy Storage System (FESS). The FESS is designed for the DC MicroGrid (MG) application. It mainly consists of a flywheel with a coaxial BrushLess DC (BLDC) machine, a three-phase full-bridge circuit, and a bidirectional Buck-Boost converter. A model-independent controller based on the ADRCT, which can estimate and compensate model uncertainties and unknown disturbances in real time, is designed for the bidirectional Buck-Boost converter control in the FESS. Simulations and experiments are conducted in both charge and discharge mode to verify the performance of the proposed controller by comparison with a traditional double loop PI controller. Results show that the new controller is more robust and more adaptive. It has a better anti-disturbance capability and a higher dynamic performance than the PI controller. Moreover, to adapt to different applications and operating conditions, the charging process of the FESS is further improved. Strategies on maximum torque control and power limiting control are developed and realized on the experimental platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Cited by
Disturbance/Uncertainty Estimation and Attenuation Techniques in PMSM Drives—A Survey
Yang, J., Chen, W.-H., Li, S., Guo, L., & Yan, Y. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2583412 · Cited by 695
A Review of Flywheel Energy Storage System Technologies and Their Applications
Amiryar, M., & Pullen, K. (2017) · Applied Sciences · doi:10.3390/app7030286 · Cited by 563
A comprehensive review of Flywheel Energy Storage System technology
Mousavi G, S. M., Faraji, F., Majazi, A., & Al-Haddad, K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.09.060 · Cited by 449
Review on Advanced Control Technologies for Bidirectional DC/DC Converters in DC Microgrids
Xu, Q., Vafamand, N., Chen, L., Dragicevic, T., Xie, L., & Blaabjerg, F. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2978064 · Cited by 439
Arani, A. A. K., Karami, H., Gharehpetian, G. B., & Hejazi, M. S. A. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.166 · Cited by 399
Metadata
- Authors
- Chang, X., Li, Y., Zhang, W., Wang, N., & Xue, W.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-02
- Volume
- 62
- Issue
- 2
- Pages
- 991-1001
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2067059420
- Cited by
- 198
- References
- 1
- FWCI
- 18.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Active Disturbance Rejection Control for a Flywheel Energy Storage System. https://app.cochat.ai/papers/10.1109/tie.2014.2336607
- The paper
- Chang, X., Li, Y., Zhang, W., Wang, N., & Xue, W. (2015). Active Disturbance Rejection Control for a Flywheel Energy Storage System. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2014.2336607
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.