Optimized Reactive Power Flow of DFIG Power Converters for Better Reliability Performance Considering Grid Codes
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
If there is no reactive power exchange between a doubly fed induction generator (DFIG) and a grid, the various characteristics of the power converters in a DFIG wind turbine system cause the lifetime expectancy of a rotor-side converter (RSC) to be significantly less than that of a grid-side converter (GSC). In order to fulfill modern grid codes, over-excited reactive power injection will further reduce the lifetime of the RSC. In this paper, the additional stress of a power semiconductor due to the reactive power injection is first evaluated in terms of a modulation index and the current loading. Then, an optimized reactive power flow is proposed in the case where an over-excited reactive power support is applied with the joint compensation from both the RSC and the GSC. Finally, some experimental validations are performed at a downscale DFIG prototype. It is concluded that, among the different combined reactive power support strategies, the best scheme will tradeoff the lifetime between the GSC and the RSC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ma, K., Liserre, M., Blaabjerg, F., & Kerekes, T. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2312335 · Cited by 460 · cited 2×
“…cycles of a power device are provided in traction systems from a thermal stress point of view, and the most important factors affecting the lifetime are summarized in [16] (e.g., mean junction temperature, junction temperature fluctuation, the ON-state time duration of a periodical current, etc.).”
BackgroundSelf-citationReliability Calculation of Multilevel Converters: Theory and Applications
Richardeau, F., & Pham, T. T. L. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2211315 · Cited by 212
Cited by
Zhou, D., Wang, H., & Blaabjerg, F. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2769161 · Cited by 200
“research efforts have been devoted to the reliability prediction of electronic equipment [13]–[19].”
BackgroundSelf-citationDong, Y., Yang, H., Li, W., & He, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2833019 · Cited by 39
Chen, G., & Cai, X. (2018) · IEEE Access · doi:10.1109/access.2018.2789421 · Cited by 30
“In [27], an optimized reactive power flow was proposed to smooth thermal stresses of a converter.”
Metadata
- Authors
- Zhou, D., Blaabjerg, F., Lau, M., & Tonnes, M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-03
- Volume
- 62
- Issue
- 3
- Pages
- 1552-1562
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2163291164
- Cited by
- 108
- References
- 2
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimized Reactive Power Flow of DFIG Power Converters for Better Reliability Performance Considering Grid Codes. https://app.cochat.ai/papers/10.1109/tie.2014.2359911
- The paper
- Zhou, D., Blaabjerg, F., Lau, M., & Tonnes, M. (2015). Optimized Reactive Power Flow of DFIG Power Converters for Better Reliability Performance Considering Grid Codes. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2014.2359911
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.