Cited by 212Multilevel Inverters and ConvertersReliability and Maintenance OptimizationHVDC Systems and Fault Protection

Reliability Calculation of Multilevel Converters: Theory and Applications

Richardeau, Frederic, Pham, T. T. L.·2013·IEEE Transactions on Industrial Electronics

Abstract

Multilevel converters have many power devices and drivers. Thus, a direct reliability calculation based only on the first failure occurrence on one of the components clearly leads them to be devalued compared to two-level converters. However, taking into account that symmetrical multilevel converters such as theX-level active neutral point clamped (ANPC) family are based on imbricated and/or stacked switching cells on the one hand, with an additional center tap at the dc bus in three-phase operation on the other hand, several redundancies clearly appear which can be managed to increase the global reliability. For the first time, a general and theoretical methodology used to calculate reliability laws and failure rates and applied to compare two-, three-, and five-level topologies is proposed. Results show that the fault handling of three- and five-level three-phase topologies permits a great increase in reliability over a “relatively” short time duration, in addition to other benefits.

Integrity signals

Registry

Crossref · 10.1109/tie.2012.2211315

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Intrinsic fault tolerance in some multilevel topologies increases the reliability of these inverters.

    “However, intrinsic fault tolerance in some multilevel topologies increases the reliability of these inverters [51].”
  • Capacitor voltage balancing, suppressing circulating currents, and reduced reliability due to higher number of devices and capacitors are challenges for multilevel inverters.

    “On the other hand, the capacitor voltage balancing, suppressing circulating currents, and reduced reliability due to higher number of devices and capacitors are the challenges that need to be addressed when approaching multilevel inverters [50]-[52].”
  • By including one fault-tolerant capability, the gap between R(t) function of two-, three-, and five-level inverters remains below 0.2 for 0-25000 hours of operation.

    “It is resulted that by including one fault-tolerant capability, the gap between R(t) function of three structures remains below 0.2 for 0-25000 hours of operation.”
  • By including multiple fault-tolerant capability, the reliability of multilevel topologies surpasses two-level inverter.

    “Moreover, by including multiple fault-tolerant capability, the reliability of multilevel topologies surpasses two-level inverter.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Richardeau, F., & Pham, T. T. L.
Affiliations
Centre National de la Recherche Scientifique (FR)
Venue
IEEE Transactions on Industrial Electronics
Published
2013-10
Volume
60
Issue
10
Pages
4225-4233
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W2023285254
Cited by
212
References
15
Citations by year
2026: 6 · 2025: 13 · 2024: 13 · 2023: 17 · 2022: 13 · 2021: 30 · 2020: 23 · 2019: 21 · 2018: 18 · 2017: 14 · 2016: 16 · 2015: 12 · 2014: 13 · 2013: 3
FWCI
5.73
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Industrial Electronics (publishedVersion)
  • HAL (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Reliability and Maintenance Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
Keywords
multilevel converters, reliability calculation, failure rate, active neutral point clamped converter, redundancy, fault management, three-level converter, five-level converter, two-level converter, switching cells, power electronics reliability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review