Frequency-Adaptive Fractional-Order Repetitive Control of Shunt Active Power Filters
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Repetitive control (RC), which can achieve zero steady-state error tracking of any periodic signal with known integer period, offers active power filters (APFs) a promising accurate current control scheme to compensate the harmonic distortion caused by nonlinear loads. However, classical RC cannot exactly compensate periodic signals of variable frequency and would lead to significant performance degradation of APFs. In this paper, a fractional-order RC (FORC) strategy at a fixed sampling rate is proposed to deal with any periodic signal of variable frequency, where a Lagrange-interpolation-based fractional delay (FD) filter is used to approximate the factional delay items. The synthesis and analysis of FORC systems are also presented. The proposed FORC offers fast online tuning of the FD and the fast update of the coefficients, and then provides APFs with a simple but very accurate real-time frequency-adaptive control solution to the elimination of harmonic distortions under grid frequency variations. A case study on a single-phase shunt APF is conducted. Experimental results are provided to demonstrate the validity of the proposed FORC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344 · cited 1×
“…− vi) (10) v̇dc = 1 C icS(t) (11) where vdc, vg, and vi are the dc bus voltage, the grid voltage and the output voltage of the inverter, respectively; ic is the compensation current; L and C are the filter inductor and dc bus capacitor, respectively; and S(t) denotes the switching function with…”
BackgroundNew trends in active filters for power conditioning
Akagi, H. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.556633 · Cited by 1,663 · cited 1×
“Active power filters (APFs) that operate as controllable power sources and offer fast response to dynamic load changes are widely used to cancel power harmonics produced by nonlinear loads [1], [2].”
BackgroundSplitting the unit delay [FIR/all pass filters design]
Laakso, T. I., Valimaki, V., Karjalainen, M., & Laine, U. K. (1996) · IEEE Signal Processing Magazine · doi:10.1109/79.482137 · Cited by 1,168
Akagi, H. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.859603 · Cited by 1,011 · cited 1×
“Active power filters (APFs) that operate as controllable power sources and offer fast response to dynamic load changes are widely used to cancel power harmonics produced by nonlinear loads [1], [2].”
BackgroundAdaptive algorithms for the rejection of sinusoidal disturbances with unknown frequency
Bodson, M., & Douglas, S. C. (1997) · Automatica · doi:10.1016/s0005-1098(97)00149-0 · Cited by 521
Hornik, T., & Zhong, Q. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2089471 · Cited by 328 · cited 1×
“Ensuring the integer period of N is always the same in the presence of grid frequency variations, and variable sampling rate approach enables RC to reject harmonics completely [16]–[18].”
BackgroundZero-phase odd-harmonic repetitive controller for a single-phase PWM inverter
Zhou, K., Low, K., Wang, D., Luo, F. L., Zhang, B., & Wang, Y. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.861190 · Cited by 222 · cited 1×
“Due to its simplicity and effectiveness, a shunt APF is the most popular tool to compensate load current harmonics.”
BackgroundSelf-citationFrequency Adaptive Selective Harmonic Control for Grid-Connected Inverters
Yang, Y., Zhou, K., Wang, H., Blaabjerg, F., Wang, D., & Zhang, B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2344049 · Cited by 160
Self-citationModeling, Analysis, and Design of Multifunction Grid-Interfaced Inverters With Output LCL Filter
Zou, Z., Wang, Z., & Cheng, M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2280724 · Cited by 141
Self-citationRashed, M., Klumpner, C., & Asher, G. M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2218833 · Cited by 108 · cited 1×
“Furthermore, the Lagrange-interpolation-based FORC can be used in extensive applications, such as the feeding currents control of grid-connected converters [10], [11], [27], programmable ac power supply [28], active noise cancelation, and so on.”
MethodFractional‐order repetitive control of programmable AC power sources
Zou, Z., Zhou, K., Wang, Z., et al. (2013) · IET Power Electronics · doi:10.1049/iet-pel.2013.0429 · Cited by 70
Self-citationPerformance improvement of repetitive controlled PWM inverters: A phase‐lead compensation solution
Zhang, B., Zhou, K., Wang, Y., & Wang, D. (2008) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.572 · Cited by 64
Self-citationLoh, P. C., Tang, Y. K., Blaabjerg, F., & Wang, P. (2011) · IET Power Electronics · doi:10.1049/iet-pel.2009.0222 · Cited by 63
DFT-Based Repetitive Control of a Series Active Filter Integrated With a 12-Pulse Diode Rectifier
le Roux, A. D., Mouton, T., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2015882 · Cited by 54 · cited 1×
“Multiple resonant control can achieve zero steadystate error tracking of sinusoidal signals at selected harmonic frequencies [5]–[7].”
BackgroundFilters With Linear-Phase Properties for Repetitive Feedback
Escobar, G., Mattavelli, P., Hernández-Gómez, M., & Martinez-Rodriguez, P. R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2240634 · Cited by 54
Fractional Delay Based Repetitive Control with Application to PWM DC/AC Converters
Wang, Y., Wang, D., Zhang, B., & Zhou, K. (2007) · The proceedings of the IEEE Conference on Control Applications/The proceedings of the ... IEEE Conference on Control Applications · doi:10.1109/cca.2007.4389352 · Cited by 52 · cited 2×
“Assuming that z−N = z−Ni−F with Ni = int[N ] being the integer part of N and F = N −Ni(0 ≤ F < 1) being the fractional part of N , the FD z−F can be approximated by a Lagrange interpolation polynomial FIR filter as follows [21], [22]:”
MethodSelf-citationFIR, Allpass, and IIR Variable Fractional Delay Digital Filter Design
Kwan, H. K., & Jiang, A. (2009) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2008.2011590 · Cited by 50
Optimal Design of All-Pass Variable Fractional-Delay Digital Filters
Lee, W. R., Caccetta, L., & Rehbock, V. (2008) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2008.916686 · Cited by 29
Metadata
- Authors
- Zou, Z.-X., Zhou, K., Wang, Z., & Cheng, M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-03
- Volume
- 62
- Issue
- 3
- Pages
- 1659-1668
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W1996821618
- Cited by
- 245
- References
- 18
- FWCI
- 13.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.