The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Frequency Adaptive Selective Harmonic Control for Grid-Connected Inverters
Open accessAbstract
In this paper, a frequency adaptive selective harmonic control (FA-SHC) scheme is proposed. The FA-SHC method is developed from a hybrid SHC scheme based on the internal model principle, which can be designed for grid-connected inverters to optimally mitigate feed-in current harmonics. The hybrid SHC scheme consists of multiple parallel recursive (nk ± m)-order (k = 0,1,2,. . ., and m ≤ n/2) harmonic control modules with independent control gains, which can be optimally weighted in accordance with the harmonic distribution. The hybrid SHC, thus, offers an optimal tradeoff among cost, complexity, and also performance in terms of high accuracy, fast response, easy implementation, and compatible design. The analysis and synthesis of the hybrid SHC are addressed. More important, in order to deal with the harmonics in the presence of grid frequency variations, the hybrid SHC is transformed into the FA-SHC, being the proposed fractional-order controller, when it is implemented with a fixed sampling rate. The FA-SHC is implemented by substituting the fractional-order elements with the Lagrange-polynomial-based interpolation filters. The proposed FA-SHC scheme provides fast on-line computation and frequency adaptability to compensate harmonics in grid-connected applications, where the grid frequency is usually varying within a certain range (e.g., 50 ± 0.5 Hz). Experimental tests have demonstrated the effectiveness of the proposed FA-SHC scheme in terms of accurate frequency adaptability and also fast transient response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Splitting the unit delay [FIR/all pass filters design]
Laakso, T. I., Valimaki, V., Karjalainen, M., & Laine, U. K. (1996) · IEEE Signal Processing Magazine · doi:10.1109/79.482137 · Cited by 1,168 · cited 3×
“The delay z − F with a fractional order number F can be well approximated by a Lagrange interpolation based filter [43], [44].”
Cited by
Power Quality Control of Smart Hybrid AC/DC Microgrids: An Overview
Nejabatkhah, F., Li, Y. W., & Tian, H. (2019) · IEEE Access · doi:10.1109/access.2019.2912376 · Cited by 258
Anurag, A., Yang, Y., & Blaabjerg, F. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2428432 · Cited by 153
Self-citation
Metadata
- Authors
- Yang, Y., Zhou, K., Wang, H., Blaabjerg, F., Wang, D., & Zhang, B.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-07
- Volume
- 30
- Issue
- 7
- Pages
- 3912-3924
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2154813364
- Cited by
- 160
- References
- 1
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency Adaptive Selective Harmonic Control for Grid-Connected Inverters. https://app.cochat.ai/papers/10.1109/tpel.2014.2344049
- The paper
- Yang, Y., Zhou, K., Wang, H., Blaabjerg, F., Wang, D., & Zhang, B. (2015). Frequency Adaptive Selective Harmonic Control for Grid-Connected Inverters. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2014.2344049
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.