Fault Detection for IGBT Using Adaptive Thresholds During the Turn-on Transient
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper presents the analysis and design of an electronic failure detection system applied to the insulated gate bipolar transistor (IGBT), this proposal is based on the direct measurement of behavior of the gate signal during the turn-on transient. The failures by short-circuit and open-circuit devices only are considered in this paper. To achieve early detection, the IGBT gate signal behavior during turn-on transient is used and to increase the effectiveness of the detection and to tolerate the variations of input to system, adaptable thresholds have been added to the analog electronics circuit implemented. The experimental tests are presented in order to validate the proposed fault-detection technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
Cited by
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“Also for such faults, methodologies can be classified into model-based [21]–[25], [29]–[36] and model-free methods [12]–[20], [26]–[28].”
MethodA Comprehensive Study of Short-Circuit Ruggedness of Silicon Carbide Power MOSFETs
Romano, G., Fayyaz, A., Riccio, M., Maresca, L., Breglio, G., Castellazzi, A., & Irace, A. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2563220 · Cited by 270
Open-Circuit IGBT Fault Detection and Location Isolation for Cascaded Multilevel Converters
Lamb, J., & Mirafzal, B. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674629 · Cited by 170
“cause extensive damage to an entire system [1], [6], [13], [17], [18], [20].”
BackgroundInfluentialWu, F., & Zhao, J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2587339 · Cited by 82
“The strong reliability demand of power device makes the development of fault diagnosis methods become a hotspot during the last years [6]–[9].”
BackgroundLiang, Y., Wang, R., & Hu, B. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3003058 · Cited by 54
“An early fault detection by analyzing the insulated gate bipolar transistor (IGBT) gate signal behavior during turn-ON transient has been proposed for one specific switch tube diagnosis [25].”
Background
Metadata
- Authors
- Rodríguez-Blanco, M. A., Vázquez-Pérez, A., Hernández-González, L., Golikov, V., Aguayo-Alquicira, J., & May-Alarcón, M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-03
- Volume
- 62
- Issue
- 3
- Pages
- 1975-1983
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W1970849593
- Cited by
- 113
- References
- 3
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.