Cited by 54Multilevel Inverters and ConvertersHVDC Systems and Fault ProtectionFault Detection and Control Systems

Single-Switch Open-Circuit Diagnosis Method Based on Average Voltage Vector for Three-Level T-Type Inverter

Liang, Yiqing, Wang, Rongkun, Hu, Bingtao·2021·IEEE Transactions on Power Electronics

Abstract

Fault-tolerant control strategy plays a significant role in improving the reliability of three-level T-type inverter where fault diagnosis method is the key and a research hotspot. Load power factor variation and modulation index regulation have great effect on conventional load current based diagnosis methods. Therefore, this article proposes a novel voltage vector based method for single-switch open-circuit fault diagnosis in three-level T-type inverter. Average output voltage vector calculated by voltages between dc-link neutral-point and bridge output terminals is taken as the eigenvector in the procedure and failed switch can be located by three diagnosis variables including angle of eigenvector, normalized modulus of eigenvector, and neutral-point potential. These variables will be some certain values under circuit fault, which are defined as eigenvalues. The vector trajectory prediction technology is utilized for threshold setting, by which the diagnosis is suitable for different power factors and different modulation indices. The strategy of redundant vector replacement is applied to realize fault-tolerant operation and verifying the proposed scheme. Simulations and experiments are carried out to illustrate the superiorities of the proposal.

Integrity signals

Registry

Crossref · 10.1109/tpel.2020.3003058

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Open-switch fault may result in current distortion, abnormal load operation, overheating, decreased efficiency, and motor output torque gap, resulting in large torque ripple or even braking torque.

    “The open-switch fault may result in current distortion, abnormal load operation, overheating, decreased efficiency and the motor output irresistible torque gap, resulting in large torque ripple or even braking torque [22], [251].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Liang, Y., Wang, R., & Hu, B.
Affiliations
Huaqiao University (CN)
Venue
IEEE Transactions on Power Electronics
Published
2021-01
Volume
36
Issue
1
Pages
911-921
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W3036775043
Cited by
54
References
28
Citations by year
2026: 4 · 2025: 14 · 2024: 9 · 2023: 10 · 2022: 13 · 2021: 3 · 2020: 1
FWCI
2.32
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Power Electronics (publishedVersion)
Funders
  • National Natural Science Foundation of China (51707068)
  • Natural Science Foundation of Fujian Province (2017J01097)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
  • Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
Keywords
open-circuit fault diagnosis, three-level T-type inverter, eigenvector method, fault-tolerant control, threshold setting, modulation index, power factor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review