Two-Stage Solar Photovoltaic-Based Stand-Alone Scheme Having Battery as Energy Storage Element for Rural Deployment
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Solar photovoltaic (PV)-based stand-alone systems have evolved as a promising solution to the issue of electrification in areas where the grid is not available. The major challenges in designing such systems are as follows: 1) extraction of maximum power from the PV array; 2) protection of the battery from overcharge and overdischarge; 3) dc to ac conversion; and 4) provision for adequate voltage boosting. As multiple objectives are required to be satisfied, the existing schemes for stand-alone systems require a minimum of three converter stages, leading to considerable reduction in the reliability and efficiency of the system. In order to address this issue, a two-stage stand-alone scheme consisting of a novel transformer-coupled dual-input converter (TCDIC) followed by a conventional full-bridge inverter is proposed in this paper. The proposed TCDIC can realize maximum power point tracking and battery charge control while maintaining the proper voltage level at the load terminal. The small signal mathematical model of the TCDIC is derived. A suitable control strategy for the proposed TCDIC is devised. The operation of the scheme is verified by performing detailed simulation studies. A laboratory prototype of the scheme is developed. Detailed experimental validation of the scheme utilizing the laboratory prototype is carried out to confirm the viability of the scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of Nonisolated High-Step-Up DC/DC Converters in Photovoltaic Grid-Connected Applications
Li, W., & He, X. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049715 · Cited by 1,423 · cited 1×
“Furthermore, the application of a high voltage level for the PV array and/or battery demands an involved design for the system to adhere to the safety of personnel and equipment [11], [12].”
Background
Cited by
Manandhar, U., Tummuru, N. R., Kollimalla, S. K., Ukil, A., Beng, G. H., & Chaudhari, K. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2750622 · Cited by 227
“With the increased concern about fossil fuel based energy usage, the design of electrical power system focuses on increasing the utilization of renewable energy sources (RESs) [1].”
BackgroundDual-Transformer-Based Asymmetrical Triple-Port Active Bridge (DT-ATAB) Isolated DC–DC Converter
Jakka, V. N. S. R., Shukla, A., & Demetriades, G. D. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674586 · Cited by 160
“However, in such converters, the voltage levels of different ports are not flexible and achieving soft switching is difficult [13], [14].”
Background
Metadata
- Authors
- Debnath, D., & Chatterjee, K.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-07
- Volume
- 62
- Issue
- 7
- Pages
- 4148-4157
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2167994247
- Cited by
- 177
- References
- 1
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two-Stage Solar Photovoltaic-Based Stand-Alone Scheme Having Battery as Energy Storage Element for Rural Deployment. https://app.cochat.ai/papers/10.1109/tie.2014.2379584
- The paper
- Debnath, D., & Chatterjee, K. (2015). Two-Stage Solar Photovoltaic-Based Stand-Alone Scheme Having Battery as Energy Storage Element for Rural Deployment. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2014.2379584
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.