Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Dual-Transformer-Based Asymmetrical Triple-Port Active Bridge (DT-ATAB) Isolated DC–DC Converter

Jakka, Venkat Nag Someswar Rao, Shukla, Anshuman, Demetriades, Georgios D. · 2017 · IEEE Transactions on Industrial Electronics

Abstract

In this paper, a dual-transformer-based asymmetrical triple-port active bridge converter (DT-ATAB) is proposed to interface two different dc-sources and a load. DT-ATAB consists of three active power electronic converters and two high-frequency transformers. All switches of these converters can be turned on with zero-voltage switching to reduce the switching losses. The bidirectional power flow operation is possible between the ports. The DT-ATAB also reduces the circulating powers between the ports for well-matched transformer turns ratios as compared to those in the other existing triple-port active bridge converters (TAB). Furthermore, the magnetic short-circuit conditions arising in the three-winding transformer of the TAB are mitigated in DT-ATAB. The principle of operation, steady-state analysis, various modes of operation (three-port and two-port modes), and a closed loop controller of DT-ATAB are presented. The theoretical analysis of this paper is verified using both simulation and experimental studies. The illustrated results show that DT-ATAB can be used as a promising multiport converter to interface the multiple sources and load to achieve wide-ranging outputs with the minimal losses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2017.2674586

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 160

Metadata

Authors
Jakka, V. N. S. R., Shukla, A., & Demetriades, G. D.
Venue
IEEE Transactions on Industrial Electronics
Published
2017-06
Volume
64
Issue
6
Pages
4549-4560
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W2589551667
Cited by
160
References
2
FWCI
4.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dual-Transformer-Based Asymmetrical Triple-Port Active Bridge (DT-ATAB) Isolated DC–DC Converter. https://app.cochat.ai/papers/10.1109/tie.2017.2674586
The paper
Jakka, V. N. S. R., Shukla, A., & Demetriades, G. D. (2017). Dual-Transformer-Based Asymmetrical Triple-Port Active Bridge (DT-ATAB) Isolated DC–DC Converter. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2017.2674586

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.