The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A Nonisolated Three-Port DC–DC Converter and Three-Domain Control Method for PV-Battery Power Systems
Abstract
In order to interface one photovoltaic (PV) port, one bidirectional battery port, and one load port of a PV-battery dc power system, a novel nonisolated three-port dc/dc converter named boost bidirectional buck converter (B3C) and its control method based on three-domain control are proposed in this paper. The power flow and operating principles of the proposed B3C are analyzed in detail, and then, the dc voltage relation between three ports is deduced. The proposed converter features high integration and single-stage power conversion from both PV and battery ports to the load port, thus leading to high efficiency. The current of all three ports is continuous; hence, the electromagnetic noise can be reduced. Furthermore, the control and modulation method for B3C has been proposed for realizing maximum power point tracking (MPPT), battery management, and bus voltage regulation simultaneously. The operation can be transited between conductance mode and MPPT mode automatically according to the load power. Finally, experimental verifications are given to illustrate the feasibility and effectiveness of the proposed topology and control method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new ZVS bidirectional DC-DC converter for fuel cell and battery application
Peng, F. Z., Li, H., Su, G.-J., & Lawler, J. S. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820550 · Cited by 782
Modeling and Control of Three-Port DC/DC Converter Interface for Satellite Applications
Qian, Z., Abdel-Rahman, O., Al-Atrash, H., & Batarseh, I. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2033926 · Cited by 399
New DC–DC converter for energy storage system interfacing in fuel cell hybrid electric vehicles
Marchesoni, M., & Vacca, C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886650 · Cited by 263
Multiple port DC DC converter for spacecraft Power Conditioning Unit
Mourra, O., Fernandez, A., Tonicello, F., & Landstroem, S. (2012) · 2012 Twenty-Seventh Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2012.6165983 · Cited by 29
Cited by
Energy storage system: Current studies on batteries and power condition system
Zhang, C., Wei, Y.-L., Cao, P.-F., & Lin, M.-C. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.10.030 · Cited by 493
Review of Multiport Converters for Solar and Energy Storage Integration
Bhattacharjee, A. K., Kutkut, N., & Batarseh, I. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2830788 · Cited by 423
Metadata
- Authors
- Zhu, H., Zhang, D., Zhang, B., & Zhou, Z.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-08
- Volume
- 62
- Issue
- 8
- Pages
- 4937-4947
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2064336853
- Cited by
- 232
- References
- 4
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Nonisolated Three-Port DC–DC Converter and Three-Domain Control Method for PV-Battery Power Systems. https://app.cochat.ai/papers/10.1109/tie.2015.2393831
- The paper
- Zhu, H., Zhang, D., Zhang, B., & Zhou, Z. (2015). A Nonisolated Three-Port DC–DC Converter and Three-Domain Control Method for PV-Battery Power Systems. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2015.2393831
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.