Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 298

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Optimized Operation of Current-Fed Dual Active Bridge DC–DC Converter for PV Applications

Open access
Shi, Yuxiang, Li, Rui, Xue, Yaosuo, Li, Hui·2015·IEEE Transactions on Industrial Electronics

Abstract

The current-fed dual active bridge (CF-DAB) dc-dc converter gains growing applications in photovoltaic (PV) and energy storage systems due to its advantages, e.g., a wide input voltage range, a high step-up ratio, a low input current ripple, and a multiport interface capability. In addition, the direct input current controllability and extra control freedom of the CF-DAB converter make it possible to buffer the double-line-frequency energy in grid-interactive PV systems without using electrolytic capacitors in the dc link. Therefore, a PV system achieves high reliability and highly efficient maximum power point tracking. This paper studies the optimized operation of a CF-DAB converter for a PV application in order to improve the system efficiency. The operating principle and soft-switching conditions over the wide operating range are thoroughly analyzed with phase-shift control and duty-cycle control, and an optimized operating mode is proposed to achieve the minimum root-mean-square transformer current. The proposed operating mode can extend the soft-switching region and reduce the power loss, particularly under a heavy load and a high input voltage. Moreover, the efficiency can be further improved with a higher dc-link voltage. A 5-kW hardware prototype was built in the laboratory, and experimental results are provided for verification. This paper provides a design guideline for the CF-DAB converter applied to PV systems, as well as other applications with a wide input voltage variation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2015.2432093

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 298

Metadata

Authors
Shi, Y., Li, R., Xue, Y., & Li, H.
Venue
IEEE Transactions on Industrial Electronics
Published
2015-11
Volume
62
Issue
11
Pages
6986-6995
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W1658704873
Cited by
298
References
31
FWCI
12.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimized Operation of Current-Fed Dual Active Bridge DC–DC Converter for PV Applications. https://app.cochat.ai/papers/10.1109/tie.2015.2432093
The paper
Shi, Y., Li, R., Xue, Y., & Li, H. (2015). Optimized Operation of Current-Fed Dual Active Bridge DC–DC Converter for PV Applications. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2015.2432093

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.