The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Performance Analysis and Optimization of Circulating Current Control for Modular Multilevel Converter
Abstract
The circulating current in phase legs is an inherent phenomenon of modular multilevel converters (MMCs). The circulating current affects various aspects of MMC performance, such as power losses, capacitor voltage ripples, and the required current rating of semiconductors. Existing circulating current control methods can improve MMC performance in one aspect, but they may not implement the optimal performance in various aspects. Analytically analyzing how circulating current control affects MMC performance is essential. This paper proposes an improved steady-state analysis method that considers circulating current control. The influence of circulating current control is included by considering the effects of the second-harmonic component on reference voltages. Explicit analytical expressions for various electrical quantities can be derived, and the analytical calculation curves of some MMC performance indexes concerned under varying second-harmonic reference voltages can be obtained. Accordingly, the effects of circulating current control on MMC performance can be concluded, where a theoretical foundation for the accurate design of MMC parameters is provided. In addition, the obtained analytical calculation curves can be used to evaluate different circulating current control targets and find appropriate control targets to comprehensively improve MMC performance. Both simulation and experimental results verify the validity of the proposed steady-state analysis method and the corresponding conclusions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387 · cited 2×
“The main existing circulating current control strategies are injecting second-harmonic voltages [10], injecting multiple harmonic voltages [12], [13], [15], predictive control [11], and openloop control [21].”
BackgroundMethodA New AC/AC Multilevel Converter Family
Glinka, M., & Marquardt, R. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843973 · Cited by 772
Pou, J., Ceballos, S., Konstantinou, G., Agelidis, V. G., Picas, R., & Zaragoza, J. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2336608 · Cited by 406 · cited 3×
“The main existing circulating current control strategies are injecting second-harmonic voltages [10], injecting multiple harmonic voltages [12], [13], [15], predictive control [11], and openloop control [21].”
BackgroundIlves, K., Antonopoulos, A., Harnefors, L., Norrga, S., Angquist, L., & Nee, H.-P. (2011) · IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2011.6120033 · Cited by 112
Cited by
Lyu, J., Zhang, X., Cai, X., & Molinas, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2842682 · Cited by 345
Analysis and Injection Control of Circulating Current for Modular Multilevel Converters
Wang, J., Han, X., Ma, H., & Bai, Z. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2808901 · Cited by 109
Wang, J., & Wang, P. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2870352 · Cited by 32
Zhao, F., Xiao, G., & Zhao, T. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2764950 · Cited by 23
Metadata
- Authors
- Li, X., Song, Q., Liu, W., Xu, S., Zhu, Z., & Li, X.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2016-02
- Volume
- 63
- Issue
- 2
- Pages
- 716-727
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2242559542
- Cited by
- 166
- References
- 4
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.