Selective Wireless Power Transfer for Smart Power Distribution in a Miniature-Sized Multiple-Receiver System
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
In a multiple-receiver wireless power transfer (WPT) system, determining the condition for uniform power distribution at a high transfer efficiency is a challenging issue. In this paper, a selective WPT technique using magnetic resonance coupling (MRC) is introduced for smart power delivery in a multiple-receiver system. The proposed method selectively and exclusively delivers power to only one designated receiver among multiple receivers, eliminating the cross-coupling effect and unbalanced power division problem across the receivers. This is achieved by separating the resonant frequencies of the receivers to isolate the coupling effects between coils. The power division ratio of the receivers is controlled by changing the duration time ratio for power transfer. In this paper, a one-transmitter three-receiver selective MRC system is designed and fabricated. The power distribution is demonstrated under impedance matched condition, showing a power transfer efficiency of 24%-29% at a very small coupling coefficient of 0.01 with a 12-mm-diameter receiver coil. Distance compensation and a one-way communication of time division multiple access are demonstrated for a multiple-receiver system, using the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1963) · Journal of the Franklin Institute · doi:10.1016/0016-0032(63)90675-6 · Cited by 5,770
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576 · cited 1×
“In order to deliver power to ubiquitously existent miniature devices, miniature and multiple-receiver WPT techniques have been previously explored [5]–[7] using magnetic resonance coupling (MRC) [2], [8].”
MethodMicrostrip Filters for RF/Microwave Applications
Hong, J. (2011) · Wiley eBooks · doi:10.1002/9780470937297 · Cited by 4,320
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Sample, A. P., Meyer, D. A., & Smith, J. R. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046002 · Cited by 1,808
A Critical Review of Recent Progress in Mid-Range Wireless Power Transfer
Hui, S. Y. R., Zhong, W., & Lee, C. K. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2249670 · Cited by 1,465 · cited 1×
“This is because, as the distance between the coils decreases, the coupling enters an overcoupled condition and frequency splitting occurs [25].”
BackgroundRamRakhyani, A. K., Mirabbasi, S., & Chiao, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2072782 · Cited by 945
Applications, challenges, and prospective in emerging body area networking technologies
Patel, M., & Wang, J. (2010) · IEEE Wireless Communications · doi:10.1109/mwc.2010.5416354 · Cited by 638
Beh, T. C., Kato, M., Imura, T., Oh, S., & Hori, Y. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2206337 · Cited by 502 · cited 1×
“There are many literatures on techniques to compensate for distance variation in WPT, but the methods are based on tuning the inductance or changing the frequency of the power source which is not desired due to increased complexity of the system and size [14], [26].”
Effect of Coupling Between Multiple Transmitters or Multiple Receivers on Wireless Power Transfer
Ahn, D., & Hong, S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196902 · Cited by 382 · cited 2×
“Current WPT techniques for multiple receivers focus on delivering power simultaneously to all of the devices in the system [5], [9], [10] as shown in Fig.”
MethodWireless Power Transmission With Self-Regulated Output Voltage for Biomedical Implant
Ahn, D., & Hong, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273472 · Cited by 315 · cited 1×
“In order to deliver power to ubiquitously existent miniature devices, miniature and multiple-receiver WPT techniques have been previously explored [5]–[7] using magnetic resonance coupling (MRC) [2], [8].”
MethodUltralow-Power Electronics for Biomedical Applications
Chandrakasan, A. P., Verma, N., & Daly, D. C. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160547 · Cited by 285 · cited 1×
“A 1-kΩ resistor is used as the load of the rectifier, which can represent a typical biomedical sensor application [27].”
MethodA Loosely Coupled Planar Wireless Power System for Multiple Receivers
Casanova, J., Low, Z. N., & Lin, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023633 · Cited by 256 · cited 2×
“Current WPT techniques for multiple receivers focus on delivering power simultaneously to all of the devices in the system [5], [9], [10] as shown in Fig.”
BackgroundMethodReview of energy harvesting techniques and applications for microelectronics (Keynote Address):
Mateu, L., & Moll, F. (2005) · SPIE Proceedings · doi:10.1117/12.613046 · Cited by 219
Zhang, Y., Lu, T., Zhao, Z., He, F., Chen, K., & Yuan, L. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2347966 · Cited by 196 · cited 1×
“[12] made another approach, but the system is limited to two receivers.”
BackgroundEmerging biomedical sensing technologies and their applications
Cote, G. L., Lec, R. M., & Pishko, M. V. (2003) · IEEE Sensors Journal · doi:10.1109/jsen.2003.814656 · Cited by 180 · cited 1×
“they are now becoming wearable and even implantable [3], [4].”
BackgroundHa, D., de Vries, W. N., John, S. W. M., Irazoqui, P. P., & Chappell, W. J. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9598-3 · Cited by 106 · cited 1×
“Many research groups are investigating such technologies [28]–[30], and depending on the surgical situation, an appropriate material can be chosen.”
BackgroundSelf-citationWireless Power Transfer System Adaptive to Change in Coil Separation
Lee, J., Lim, Y., Yang, W., & Lim, S.-O. (2013) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2013.2290795 · Cited by 84 · cited 3×
“There is abundant literature on methods to compensate for the change of location in a single-receiver system [13], [14], but these solutions cannot be applied to systems with multiple receivers under a simultaneous power transfer scenario.”
BackgroundEyeglasses-powered, contact lens-like platform with high power transfer efficiency
Kim, Y., Maeng, J., & Irazoqui, P. P. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9979-0 · Cited by 38 · cited 1×
“Many research groups are investigating such technologies [28]–[30], and depending on the surgical situation, an appropriate material can be chosen.”
BackgroundSelf-citationHa, D., Lee, T.-C., Webery, D. J., & Chappell, W. J. (2014) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2014.6848656 · Cited by 8 · cited 8×
“In order to deliver power to ubiquitously existent miniature devices, miniature and multiple-receiver WPT techniques have been previously explored [5]–[7] using magnetic resonance coupling (MRC) [2], [8].”
MethodInfluentialSelf-citation
Cited by
Opportunities and Challenges for Near-Field Wireless Power Transfer: A Review
Jawad, A. M., Nordin, R., Gharghan, S. K., Jawad, H. M., & Ismail, M. (2017) · Energies · doi:10.3390/en10071022 · Cited by 268
Wireless power transfer based on novel physical concepts
Song, M., Jayathurathnage, P., Zanganeh, E., Krasikova, M., Smirnov, P., Belov, P., Kapitanova, P., Simovski, C., Tretyakov, S., & Krasnok, A. (2021) · Nature Electronics · doi:10.1038/s41928-021-00658-x · Cited by 190
An Overview of Resonant Circuits for Wireless Power Transfer
Jiang, C., Chau, K. T., Liu, C., & Lee, C. H. T. (2017) · Energies · doi:10.3390/en10070894 · Cited by 186
“However, for so e practical applications, the sel ctive wireless power transf r is requir d to feed the targeted receiver [74,75].”
BackgroundAbou Houran, M., Yang, X., & Chen, W. (2018) · Electronics · doi:10.3390/electronics7110296 · Cited by 170
“To overcome this issue, a selective tec nique for smart power delivery to multiple receivers is presented [163].”
Background
Metadata
- Authors
- Kim, Y.-J., Ha, D., Chappell, W. J., & Irazoqui, P. P.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2016-03
- Volume
- 63
- Issue
- 3
- Pages
- 1853-1862
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2258738680
- Cited by
- 175
- References
- 20
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.