A Modular Multilevel DC-Link Front-to-Front DC Solid-State Transformer Based on High-Frequency Dual Active Phase Shift for HVDC Grid Integration
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper proposes a modular multilevel dc-link dc solid-state transformer (MADCT) based on high-frequency dual active phase shift for HVDC grid integration. The proposed MADCT employs one arm of modular multilevel converter as HVDC active front-end interface and dual active bridge as high-frequency power transfer link, which brings many advantages and makes the operation of MADCT quiet different with traditional dc transformers. Compared with the traditional dc transformer schemes, the MADCT not only has good modularity and flexibility but also has good fault handling capacity. Especially, the performances of current stress, power transfer capacitor, and efficiency are improved. The topology, operation principle, voltage, current, power performances, and control and parameter design are presented and analyzed comprehensively in this paper. At last, a MADCT prototype is built and the experimental results verify the correctness and effectively of the proposed solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Self-citation
Cited by
Hou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
Modeling and Advanced Control of Dual-Active-Bridge DC–DC Converters: A Review
Shao, S., Chen, L., Shan, Z., Gao, F., Chen, H., Sha, D., & Dragičević, T. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3108157 · Cited by 488
Circulating Current and ZVS-on of a Dual Active Bridge DC-DC Converter: A Review
Shao, S., Chen, H., Wu, X., Zhang, J., & Sheng, K. (2019) · IEEE Access · doi:10.1109/access.2019.2911009 · Cited by 200
“SSTs based on DABs in power grids have been introduced to interconnect different scale micro-grids [6], [10], [11] or to connect different level of dc grids [12]–[17].”
BackgroundLin, N., Liu, P., & Dinavahi, V. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2967687 · Cited by 27
“The solid-state transformer (SST) based on the modular power converter topology and medium-frequency transformer (MFT) [17], [18] has a high homogeneity that provides parallelism, which is potentially a solution to efficient simulation.”
BackgroundHaritha, G., Kumaravel, S., & Ashok, S. (2018) · 2018 2nd International Conference on Green Energy and Applications (ICGEA) · doi:10.1109/icgea.2018.8356290 · Cited by 5
Metadata
- Authors
- Zhao, B., Song, Q., Li, J., & Liu, W.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-11
- Volume
- 64
- Issue
- 11
- Pages
- 8919-8927
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2543196354
- Cited by
- 107
- References
- 1
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.