The DOI matches its Crossref record.
Synchronverters With Better Stability Due to Virtual Inductors, Virtual Capacitors, and Anti-Windup
Abstract
Synchronverters are inverters that mimic the behavior of synchronous generators. In this paper, we propose five modifications to the synchronverter algorithm from the paper “Synchronverters: Inverters that mimic synchronous generators,” (IEEE Trans. Ind. Electron., vol. 58, no. 4, pp. 1259-1267, Apr. 2011), to improve its stability and performance. These modifications are implemented in software and do not require any changes in the inverter hardware. The first two modifications concern the control of the virtual field current in the synchronverter so that it is more robust to faults. We prove the stability of the grid-connected synchronverter with this improved field current controller. The third modification is to increase the effective size of the filter inductors virtually. This is motivated using results from the stability analysis of a constant field current synchronous generator connected to an ac power grid and also by practical considerations. Simulations and experiments show that this leads to a much better response to changes in grid frequency, voltage, or to imbalance in the grid. The fourth modification is to change the formula for the (virtual) nominal active mechanical torque to take into account the (virtual) losses in the output impedance of the converter. This makes the tracking of the desired active power much more accurate. The fifth modification is to introduce virtual capacitors in series with the inverter outputs to filter spurious dc components from the current supplied to the grid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Virtual Inertia: Current Trends and Future Directions
Tamrakar, U., Shrestha, D., Maharjan, M., Bhattarai, B., Hansen, T., & Tonkoski, R. (2017) · Applied Sciences · doi:10.3390/app7070654 · Cited by 640
Future low-inertia power systems: Requirements, issues, and solutions - A review
Ratnam, K. S., Palanisamy, K., & Yang, G. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109773 · Cited by 474
Research Roadmap on Grid-Forming Inverters
Lin, Y., Eto, J., Johnson, B., Flicker, J., Lasseter, R., Villegas Pico, H., Seo, G.-S., Pierre, B., & Ellis, A. (2020) · doi:10.2172/1721727 · Cited by 419
Improvement of Frequency Regulation in VSG-Based AC Microgrid Via Adaptive Virtual Inertia
Hou, X., Sun, Y., Zhang, X., Lu, J., Wang, P., & Guerrero, J. M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2923734 · Cited by 367
Evolution of microgrids with converter-interfaced generations: Challenges and opportunities
Hossain, M. A., Pota, H. R., Hossain, M. J., & Blaabjerg, F. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.01.038 · Cited by 309
Metadata
- Authors
- Natarajan, V., & Weiss, G.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-07
- Volume
- 64
- Issue
- 7
- Pages
- 5994-6004
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2590702350
- Cited by
- 182
- References
- 0
- FWCI
- 12.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Synchronverters With Better Stability Due to Virtual Inductors, Virtual Capacitors, and Anti-Windup. https://app.cochat.ai/papers/10.1109/tie.2017.2674611
- The paper
- Natarajan, V., & Weiss, G. (2017). Synchronverters With Better Stability Due to Virtual Inductors, Virtual Capacitors, and Anti-Windup. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2017.2674611
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.