CoChat

An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope

Basar, Md. Rubel, Ahmad, Mohd Yazed, Cho, Jongman, Ibrahim, Fatimah · 2018 · IEEE Transactions on Industrial Electronics
Cited by 208

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Magnetic resonant-based wireless power transfer system (WPTS) is an efficient way to energize critical biomedical devices, such as wireless capsule endoscopes, where a direct wire connection is not practical. However, low power transfer efficiency (PTE) and poor received power stability (RPS) are usually the main bottlenecks of WPTS in this application. Thus, this paper proposes an efficient WPTS that tremendously improves the PTE and enriches the RPS. In order to improve the PTE, an optimum three-coil inductive link is adopted with a compact wearable power transmitting coil-I (PTC-I) and a 2-3D power receiving coil. As a result, the stability is improved with the new configuration of the power transmission coil-III (PTC-III) and power combining technique at the receiving side. To confirm the validity of the proposed design, proof-of-concept prototypes were implemented for an experimental test. Results obtained from the experimental test assured that the proposed PTC-I-based system achieved a PTE of more than 8% while transferring 758 mW of power with 68.7% RPS. The best overall RPS attained by the proposed PTC-III based system is 79.2%. This system achieved a PTE of 5.4% transferring at least 570 mW of power. In comparison, the performance of the proposed designs greatly outweighs the previous designs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2018.2801781

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 208

Metadata

Authors
Basar, M. R., Ahmad, M. Y., Cho, J., & Ibrahim, F.
Venue
IEEE Transactions on Industrial Electronics
Published
2018-10
Volume
65
Issue
10
Pages
7772-7781
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W2786107417
Cited by
208
References
19
FWCI
6.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope. https://app.cochat.ai/papers/10.1109/tie.2018.2801781
The paper
Basar, M. R., Ahmad, M. Y., Cho, J., & Ibrahim, F. (2018). An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2018.2801781

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.