An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Magnetic resonant-based wireless power transfer system (WPTS) is an efficient way to energize critical biomedical devices, such as wireless capsule endoscopes, where a direct wire connection is not practical. However, low power transfer efficiency (PTE) and poor received power stability (RPS) are usually the main bottlenecks of WPTS in this application. Thus, this paper proposes an efficient WPTS that tremendously improves the PTE and enriches the RPS. In order to improve the PTE, an optimum three-coil inductive link is adopted with a compact wearable power transmitting coil-I (PTC-I) and a 2-3D power receiving coil. As a result, the stability is improved with the new configuration of the power transmission coil-III (PTC-III) and power combining technique at the receiving side. To confirm the validity of the proposed design, proof-of-concept prototypes were implemented for an experimental test. Results obtained from the experimental test assured that the proposed PTC-I-based system achieved a PTE of more than 8% while transferring 758 mW of power with 68.7% RPS. The best overall RPS attained by the proposed PTC-III based system is 79.2%. This system achieved a PTE of 5.4% transferring at least 570 mW of power. In comparison, the performance of the proposed designs greatly outweighs the previous designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RamRakhyani, A. K., Mirabbasi, S., & Chiao, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2072782 · Cited by 945 · cited 3×
“makers [8], [9], the low power transfer efficiency (PTE) and poor received power stability (RPS) are the key challenges of”
BackgroundMethodInfluentialDesign and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 591 · cited 5×
“In order to minimize this effect and maximize the PTE, multicoil (four-coil or three-coil) inductive link [8], [22] could be adopted, which has not been fully investigated in a WCE platform.”
BackgroundMethodInfluentialXue, R.-F., Cheng, K.-W., & Je, M. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2012.2209297 · Cited by 340 · cited 1×
“However, unlike in other biomedical implantable devices [4], such as retinal implants [5], neural recorders [6], [7], and pace-”
BackgroundWireless Power Transmission With Self-Regulated Output Voltage for Biomedical Implant
Ahn, D., & Hong, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273472 · Cited by 315 · cited 1×
“However, unlike in other biomedical implantable devices [4], such as retinal implants [5], neural recorders [6], [7], and pace-”
BackgroundAnalysis, Design, and Control of a Transcutaneous Power Regulator for Artificial Hearts
Chen, Q., Wong, S. C., Tse, C. K., & Ruan, X. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2006492 · Cited by 244 · cited 1×
“makers [8], [9], the low power transfer efficiency (PTE) and poor received power stability (RPS) are the key challenges of”
BackgroundSun, T., Xie, X., Li, G., Gu, Y., Deng, Y., & Wang, Z. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2206809 · Cited by 148
Deng, Q., Liu, J., Czarkowski, D., Kazimierczuk, M. K., Bojarski, M., Zhou, H. L., & Hu, W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2518126 · Cited by 147 · cited 1×
“Along with the new design and configuration, the litz wire was used for the implementation of coils, which improved the quality factor by minimizing the coil’s ac resistance caused by skin and proximity effects [24].”
MethodNa, K., Jang, H., Ma, H., & Bien, F. D. (2014) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2014.2365475 · Cited by 144 · cited 1×
“Although, a four-coil-based magnetic resonant WPTS was presented in [16] for biomedical WCE application, nonetheless, the obtained low PTE 0.”
Basar, M. R., Ahmad, M. Y., Cho, J., & Ibrahim, F. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2614268 · Cited by 122 · cited 2×
“This PTC is designed and optimized by the method given in [2].”
MethodSelf-citationApplication of Wireless Power Transmission Systems in Wireless Capsule Endoscopy: An Overview
Basar, M. R., Ahmad, M. Y., Cho, J., & Ibrahim, F. (2014) · Italian National Conference on Sensors · doi:10.3390/s140610929 · Cited by 102 · cited 7×
“To meet these goals, most of the existing studies use typical Helmholtz coil (THC) [3], [13], [14] as shown in Fig.”
MethodSelf-citation
Cited by
Robotic wireless capsule endoscopy: recent advances and upcoming technologies
Cao, Q., Deng, R., Pan, Y., Liu, R., Chen, Y., Gong, G., Zou, J., Yang, H., & Han, D. (2024) · Nature Communications · doi:10.1038/s41467-024-49019-0 · Cited by 165
Pahlavan, S., Shooshtari, M., Maleki, M., & Jafarabadi Ashtiani, S. (2022) · Electronics · doi:10.3390/electronics11081204 · Cited by 20
Metadata
- Authors
- Basar, M. R., Ahmad, M. Y., Cho, J., & Ibrahim, F.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2018-10
- Volume
- 65
- Issue
- 10
- Pages
- 7772-7781
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2786107417
- Cited by
- 208
- References
- 19
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope. https://app.cochat.ai/papers/10.1109/tie.2018.2801781
- The paper
- Basar, M. R., Ahmad, M. Y., Cho, J., & Ibrahim, F. (2018). An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2018.2801781
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.