CoChat

A Two-Hop Wireless Power Transfer System With an Efficiency-Enhanced Power Receiver for Motion-Free Capsule Endoscopy Inspection

Tianjia Sun, Xiang Xie, Guolin Li, Yingke Gu, Yangdong Deng, Zhihua Wang · 2012 · IEEE Transactions on Biomedical Engineering
Cited by 148

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

This paper presents a wireless power transfer system for a motion-free capsule endoscopy inspection. Conventionally, a wireless power transmitter in a specifically designed jacket has to be connected to a strong power source with a long cable. To avoid the power cable and allow patients to walk freely in a room, this paper proposes a two-hop wireless power transfer system. First, power is transferred from a floor to a power relay in the patient's jacket via strong coupling. Next, power is delivered from the power relay to the capsule via loose coupling. Besides making patients much more conformable, the proposed techniques eliminate the sources of reliability issues arisen from the moving cable and connectors. In the capsule, it is critical to enhance the power conversion efficiency. This paper develops a switch-mode rectifier (rectifying efficiency of 93.6%) and a power combination circuit (enhances combining efficiency by 18%). Thanks to the two-hop transfer mechanism and the novel circuit techniques, this system is able to transfer an average power of 24 mW and a peak power of 90 mW from the floor to a 13 mm × 27 mm capsule over a distance of 1 m with the maximum dc-to-dc power efficiency of 3.04%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2012.2206809

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 41

  1. nakamoto, 2006, A passive UHF RFID tag LSI with 36.6% efficiency CMOS-only rectifier and current-mode demodulator in 0.35 um FeRAM technology, Proc Int Conf Solid-State Circuits, 1201
  2. 10.1109/TBCAS.2010.2072782 · DOI · Paper page
  3. 10.1109/TCSII.2010.2048403 · DOI · Paper page
  4. 10.1109/TAP.2010.2044321 · DOI
  5. 10.1109/APCCAS.2010.5774924 · doi:10.1109/apccas.2010.5774924
  6. 10.1109/TPEL.2009.2017195 · DOI · Paper page
  7. 10.1109/TIE.2011.2112317 · DOI · Paper page
  8. 10.1109/TMAG.2010.2093534 · DOI · Paper page
  9. 10.1109/TMAG.2010.2087010 · DOI · Paper page
  10. 10.1109/LAWP.2010.2068534 · doi:10.1109/lawp.2010.2068534
  11. 10.1109/ASSCC.2011.6123644 · doi:10.1109/asscc.2011.6123644
  12. 10.1109/JSSC.2004.835822 · DOI · Paper page
  13. 10.1016/j.proeng.2011.12.247 · doi:10.1016/j.proeng.2011.12.247
  14. 10.1007/s11517-007-0223-9 · DOI
  15. sun, 2010, An asymmetric resonant coupling wireless power transmission link for Micro-Ball endoscopy, Proc Int Conf Eng Med Biol Soc, 6531
  16. 10.1109/ICMA.2011.5985662 · DOI
  17. 10.1109/TBME.2008.919721 · DOI
  18. 10.1109/TBCAS.2009.2034364 · DOI
  19. 10.1109/ISSCC.2010.5434028 · DOI · Paper page
  20. 10.1109/ISSCC.2009.4977424 · DOI · Paper page
  21. 10.1109/TIE.2008.2010110 · DOI · Paper page
  22. 10.1016/j.bios.2009.08.049 · DOI
  23. 10.1109/TCSII.2009.2032465 · DOI
  24. 10.1109/TBME.2010.2087332 · DOI
  25. 10.1016/j.sna.2011.03.036 · DOI
  26. 10.1109/TIE.2009.2023633 · DOI
  27. 10.1016/j.bios.2006.06.015 · DOI · Paper page
  28. 10.1016/j.sna.2009.12.025 · doi:10.1016/j.sna.2009.12.025
  29. 10.1088/0960-1317/21/5/054008 · DOI
  30. 10.1109/TBCAS.2008.2006493 · DOI
  31. 10.1109/ASSCC.2011.6123633 · DOI
  32. 10.1109/JSSC.2006.882884 · DOI
  33. yoo, 2009, A 5.2 mW self-configured wearable body sensor network controller and a 12 uW 54.9% efficiency wirelessly powered sensor for continuous health monitoring system, Proc Int Conf Solid-State Circuits, 290
  34. 10.1109/ISSCC.2010.5433933 · DOI · Paper page
  35. 10.1109/ISSCC.2010.5433936 · doi:10.1109/isscc.2010.5433936
  36. finkenzeller, 2003, RFID Handbook Fundamentals and Applications in Contactless Smart Cards and Identification, 10.1002/0470868023 · DOI · Paper page
  37. terman, 1943, Radio Engineers Handbook
  38. 10.1109/IEMBS.2007.4352793 · DOI
  39. ohandely, 2008, Improved wireless transcutaneous power transmission for in vivo applications, IEEE Sensor J, 8, 57, 10.1109/JSEN.2007.912899 · DOI · Paper page
  40. kurs, 2007, Wireless power transfer via strongly coupled magnetic resonances, Science, 317, 83, 10.1126/science.1143254 · DOI · Paper page
  41. 1998, ICNIRP Guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz), Health Phys, 74, 492

Cited by

See all 148

Metadata

Authors
Sun, T., Xie, X., Li, G., Gu, Y., Deng, Y., & Wang, Z.
Venue
IEEE Transactions on Biomedical Engineering
Published
2012-11
Volume
59
Issue
11
Pages
3247-3254
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2036275108
Cited by
148
References
3
FWCI
6.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Two-Hop Wireless Power Transfer System With an Efficiency-Enhanced Power Receiver for Motion-Free Capsule Endoscopy Inspection. https://app.cochat.ai/papers/10.1109/tbme.2012.2206809
The paper
Sun, T., Xie, X., Li, G., Gu, Y., Deng, Y., & Wang, Z. (2012). A Two-Hop Wireless Power Transfer System With an Efficiency-Enhanced Power Receiver for Motion-Free Capsule Endoscopy Inspection. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2012.2206809

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.