Investigation of Small-Signal Dynamics of Modular Multilevel Converter Under Unbalanced Grid Conditions
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
This paper develops a comprehensive dynamic-phasor-based small-signal model for the modular multilevel converter (MMC) system under unbalanced grid conditions, which takes into consideration the dynamics of the MMC system under a balanced grid condition as well as the other emerging internal harmonics produced by the unbalanced grid components and more complex controllers. The small-signal model is validated by comparing the time-domain responses from a detailed electromagnetic transient (EMT) simulation in PSCAD/EMTDC. Based on the eigen-analysis and PSCAD-based time-domain simulation studies, this paper reveals the poorly damped modes that cause unstable oscillations in MMC system under the unbalanced grid conditions. From the results, more poorly damped modes involved in the internal harmonics are emerging under unbalanced grid conditions compared with the modes under the balanced grid conditions, and can highly impact the system dynamic behaviors by the selection of the control parameters. It is also shown that, under the unbalanced grid conditions, the feasible region of the control parameters of the vector current control gets narrowed indicating the reduction of the stability margin, smaller (larger) value of proportional (integral) gain of the circulating current suppressing controller can enhance the system stability, and larger values of the proportional and integral gains of the negative-sequence current suppressing control can result in the harmonic instability of the MMC system. Besides, the parameters of multiple complex-coefficient filters for positive- and negative-sequence components extraction also have a big impact on the small-signal stability of the MMC system and are required to be properly selected.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Dynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188
Modulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934 · cited 1×
“(VSC)-based high-voltage direct current (HVdc) transmission systems [1]–[3].”
BackgroundZhou, J. Z., Ding, H., Fan, S., Zhang, Y., & Gole, A. M. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2330518 · Cited by 738 · cited 5×
“The small-signal dynamics of a two-level VSC station were reported under a balanced grid condition in [4] and [5], which cannot represent the internal dynamics of the MMC system, such as the capacitor voltage ripple and the circulating current.”
BackgroundMethodInfluentialGuan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549 · cited 15×
“Thus, it can be concluded that, 1) smaller (larger) values of kpcir (kicir), within the viable range, are preferable under both the balanced and unbalanced grid conditions; 2) more poorly damped modes are emerging under the unbalanced grid conditions (Case 2), which agrees with the eigen-analysis results of Table III;…”
MethodInfluentialGuo, X., Wu, W., & Chen, Z. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2041738 · Cited by 475 · cited 4×
“MCCF gains surely affect the dynamics of the MMC system and the ωi i and ωi u values are required to be properly selected according to the recommendation from [17] and the small-signal”
BackgroundMethodInfluentialDynamic Averaged and Simplified Models for MMC-Based HVDC Transmission Systems
Saad, H., Peralta, J., Dennetiere, S., Mahseredjian, J., Jatskevich, J., Martinez, J. A., Davoudi, A., Saeedifard, M., Sood, V., Wang, X., et al. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2251912 · Cited by 374 · cited 1×
“A small-signal model of MMC based on an average-value model was developed in [6] and [7], and also neglected the internal dynamics of MMC.”
MethodLi, S., Wang, X., Yao, Z., Li, T., & Peng, Z. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2329059 · Cited by 343 · cited 2×
“In this paper, a dynamic-phasor-based small-signal model for the MMC system under the unbalanced grid conditions is developed, which represents the dynamics of 1) the MMC station with consideration of the internal harmonics of [9], [10] and newly introduced harmonic components under the unbalanced grid conditions, 2)…”
BackgroundMethodYazdani, A., & Iravani, R. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.874641 · Cited by 308
Harmonic Instability in MMC-HVDC Converters Resulting From Internal Dynamics
Li, T., Gole, A. M., & Zhao, C. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2542188 · Cited by 184 · cited 20×
“(7) 3) PLL, VCC, and CCSC Model: The PLL, VCC, and CCSC of Fig.”
BackgroundMethodSelf-citation
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“This model has been recently improved using small-signal dynamics [32] and obtaining a steady-state”
MethodGeneralized Dynamic Phasor Modeling of the MMC for Small-Signal Stability Analysis
Sakinci, Ö. C., & Beerten, J. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2898468 · Cited by 95
“developed a dynamic phasor-based MMC model and used it for small-signal stability analysis under unbalanced grid conditions [12].”
MethodParameter Design Oriented Analysis of the Current Control Stability of the Weak-Grid-Tied VSC
Wu, G., Sun, H., Zhang, X., Egea‐Àlvarez, A., Zhao, B., Xu, S., Wang, S., & Zhou, X. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3009517 · Cited by 87
Zhu, J., Hu, J., Wang, S., & Wan, M. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.2976776 · Cited by 63
“The DP method has made great progress in MMC modeling, which has been introduced into the small-signal modeling of MMC systems under unbalanced grid conditions [20].”
BackgroundMethodInfluentialGuo, C., Xu, L., Yang, S., & Jiang, W. (2022) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2022.3186940 · Cited by 45
“MODULAR multilevel converter (MMC) is a type of voltage source converter (VSC), which has been widely used in high voltage direct current (HVDC) transmission system thanks to its low harmonic injection, modularity, and strong expansibility characteristics [1], [2].”
BackgroundSelf-citation
Metadata
- Authors
- Guo, C., Yang, J., & Zhao, C.
- Affiliations
- North China Electric Power University (CN)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2019-03
- Volume
- 66
- Issue
- 3
- Pages
- 2269-2279
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2802995072
- Cited by
- 53
- References
- 18
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 10 · 2023: 3 · 2022: 7 · 2021: 10 · 2020: 14 · 2019: 5
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Funders
- National Natural Science Foundation of China (51507060)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- modular multilevel converter, unbalanced grid conditions, small-signal modeling, dynamic phasor model, eigenvalue analysis, harmonic instability, circulating current suppression, negative sequence current suppression, vector current control, complex coefficient filter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.