The DOI matches its Crossref record.
A Unified Dynamic Model and Control for the Voltage-Sourced Converter Under Unbalanced Grid Conditions
Abstract
This paper introduces and develops i) a novel unified dynamic model, and ii) new control schemes for a grid-connected static energy conversion system that is based on the voltage-sourced converter (VSC) configuration. The model and the controls are applicable to both the conventional two-level and the three-level neutral point diode clamped (NPC) VSCs. The model is unified since it represents the dynamic behavior of the VSC with respect to both positiveand negative-sequence components, due to unbalanced grid conditions and disturbances. To develop the unified model, the concepts of "generalized sinusoidal pulse-width modulation (SPWM)" and "VSC sequence subsystems" are presented. Based on the negative-sequence subsystem control, a new control strategy, to either balance the ac line currents or to mitigate dc-bus voltage ripples, is introduced. Application of the developed model and the controls to a variable-speed wind-power unit is presented in the paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
Guan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549
Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit
Karimi, H., Yazdani, A., & Iravani, R. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.911774 · Cited by 377
Self-citationDefinitions and Applications of Dynamic Average Models for Analysis of Power Systems
Chiniforoosh, S., Jatskevich, J., Yazdani, A., Sood, V., Dinavahi, V., Martinez, J. A., & Ramirez, A. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2043859 · Cited by 306
Self-citationModeling and control of microgrid: An overview
Mahmoud, M. S., Azher Hussain, S., & Abido, M. A. (2014) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2014.01.016 · Cited by 279
Metadata
- Authors
- Yazdani, A., & Iravani, R.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2006-07
- Volume
- 21
- Issue
- 3
- Pages
- 1620-1629
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2153597540
- Cited by
- 308
- References
- 0
- FWCI
- 11.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Unified Dynamic Model and Control for the Voltage-Sourced Converter Under Unbalanced Grid Conditions. https://app.cochat.ai/papers/10.1109/tpwrd.2006.874641
- The paper
- Yazdani, A., & Iravani, R. (2006). A Unified Dynamic Model and Control for the Voltage-Sourced Converter Under Unbalanced Grid Conditions. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2006.874641
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.