An Evaluation Method for Voltage Dips in a Shipboard Microgrid Under Quasi-Balanced and Unbalanced Voltage Conditions
Open accessAbstract
High power motor loads are widely used in shipboard microgrids (SMGs) consuming about 70% of the generated electrical power. Voltage dips, which are usually caused by the starting current of high-power motors, are one of the main causes of onboard sensitive electrical equipment dropout. This phenomenon must be considered in design of SMGs to comply with maritime standards. In this paper, an evaluation method is proposed to estimate the expected severity of voltage dips and also generator current transient surges due to the onboard motor startups under real sea-going conditions. This is based on the Riemann-summation-principle evaluation method. The quasi-balanced and unbalanced ac bus voltage cases are carefully selected to present the actual impact of the voltage dips in real SMG. The evaluations are validated by measurements gathered from the ballast pump motor startup in the SMG. The proposed method can provide ship engineers with necessary information about the actual magnitude/depth of voltage dips. Accordingly, the allowable capacities of high-power motors can be estimated, which is beneficial to determine proper motor starter designs and improve the power quality in real SMGs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
As the assessment method in [43] is based on motor capacity and fixed SMG parameters, only an average estimate of the voltage dip severity can be obtained.
“However, as the assessment method is based on the motor capacity and fixed SMG parameters, only an average estimate of the voltage dip severity can be obtained.”
From New Horizons for Microgrids: From Rural Electrification to Space Applications (2023) · cites this paper as [43]
The Introduction says the method requires motor capacity and the SMG’s main parameters, supporting that part of the claim. But the paper does not say it can provide only an average estimate: the Introduction and Conclusions describe evaluation under quasi-balanced and unbalanced conditions, validated against measurements, and the discussion of Riemann summation addresses the mismatch between an assumed average starting current and measured current. (LLM, conf=0.85)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 32
- 10.1109/TIA.2012.2209621 · DOI
- 10.1109/TIE.2017.2669018 · DOI
- 10.1109/TIE.2012.2193863 · DOI
- 10.1049/iet-est.2010.0082 · DOI
- 10.1109/ESTS.2007.372103 · DOI
- 10.1080/15325000490228423 · DOI
- 10.1109/ISIEA.2009.5356387 · DOI
- 2017, IEEE Recommended Practice for Electrical Installations on Shipboard
- 2015, IEC Standard for Testing and Measurement Techniques Power Quality Measurement Methods
- 2016, Requirements Concerning Electrical and Electronic Installations
- 2016, Guide for Building and Classing Part 4 Vessel Systems and Machinery
- 2016, Rules for classification Ships Part 4 Systems and components Chapter 8 Electrical installations
- 2016, Rules and Regulation for Classification of Steel Ships
- 10.1109/APEC.2018.8341061 · DOI
- 10.1109/TEC.2017.2691803 · DOI
- 10.1109/IAS.2011.6074427 · DOI
- guerrero, 0, Shipboard microgrids: Maritime islanded power systems technologies, Proc Int Exhib Conf Power Electron Intell Motion Renewable Energy Energy Manage, 1
- 10.1109/IECON.2010.5675297 · DOI
- 10.1109/ESTS.2009.4906549 · DOI
- 10.1049/iet-gtd.2015.1572 · DOI
- 10.1109/TIE.2010.2066534 · DOI · Paper page
- 10.1109/TPWRS.2011.2163948 · DOI
- 10.1109/TIA.2016.2601558 · DOI
- 10.1007/s40565-015-0108-0 · DOI
- 10.1109/TTE.2016.2552720 · DOI
- 10.1109/IECON.2017.8216385 · DOI
- 10.1109/TPEL.2004.826536 · DOI
- 10.1109/TIA.2004.836302 · DOI
- 10.1109/TPEL.2007.904243 · DOI
- 10.1109/28.556647 · DOI
- 10.1109/UPEC.2014.6934738 · DOI
- 10.1016/j.epsr.2015.12.032 · DOI
Cited by
Sorted by citations
New Horizons for Microgrids: From Rural Electrification to Space Applications
Micallef, A., Guerrero, J. M., & Vasquez, J. C. (2023) · Energies · doi:10.3390/en16041966 · Cited by 31
Self-citation
Metadata
- Authors
- Liu, W., Tarasiuk, T., Su, C.-L., Gorniak, M., Savaghebi, M., Vasquez, J. C., & Guerrero, J. M.
- Affiliations
- Aalborg University (DK)
- Gdynia Maritime University (PL)
- National Kaohsiung University of Science and Technology (TW)
- University of Southern Denmark (DK)
- ORCID
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2019-10
- Volume
- 66
- Issue
- 10
- Pages
- 7683-7693
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2795700581
- Cited by
- 17
- References
- 0
- Citations by year
- 2026: 4 · 2025: 1 · 2024: 1 · 2023: 4 · 2021: 3 · 2020: 4
- FWCI
- 0.67
- Type
- journal article
- Language
- en
- Open access
- green
- vbn.aau.dk
- Licence
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- VBN Forskningsportal (Aalborg Universitet) (acceptedVersion, other-oa)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion)
- Funders
- National Science Centre, Poland (DEC-2012/07/E/ST8/01688)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power Systems and Control
- Keywords
- voltage sag, shipboard microgrids, voltage unbalance, power quality
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review