Cited by 17Power Quality and HarmonicsMicrogrid Control and OptimizationElectric Power Systems and Control

The DOI matches its Crossref record.

An Evaluation Method for Voltage Dips in a Shipboard Microgrid Under Quasi-Balanced and Unbalanced Voltage Conditions

Open access
Liu, Wenzhao, Tarasiuk, Tomasz, Su, Chun-Lien, Gorniak, Mariusz, Savaghebi, Mehdi, Vasquez, Juan Carlos, Guerrero, Josep M.·2019·IEEE Transactions on Industrial Electronics

Abstract

High power motor loads are widely used in shipboard microgrids (SMGs) consuming about 70% of the generated electrical power. Voltage dips, which are usually caused by the starting current of high-power motors, are one of the main causes of onboard sensitive electrical equipment dropout. This phenomenon must be considered in design of SMGs to comply with maritime standards. In this paper, an evaluation method is proposed to estimate the expected severity of voltage dips and also generator current transient surges due to the onboard motor startups under real sea-going conditions. This is based on the Riemann-summation-principle evaluation method. The quasi-balanced and unbalanced ac bus voltage cases are carefully selected to present the actual impact of the voltage dips in real SMG. The evaluations are validated by measurements gathered from the ballast pump motor startup in the SMG. The proposed method can provide ship engineers with necessary information about the actual magnitude/depth of voltage dips. Accordingly, the allowable capacities of high-power motors can be estimated, which is beneficial to determine proper motor starter designs and improve the power quality in real SMGs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2018.2885722

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • As the assessment method in [43] is based on motor capacity and fixed SMG parameters, only an average estimate of the voltage dip severity can be obtained.

    “However, as the assessment method is based on the motor capacity and fixed SMG parameters, only an average estimate of the voltage dip severity can be obtained.”

    From New Horizons for Microgrids: From Rural Electrification to Space Applications (2023) · cites this paper as [43]

    The Introduction says the method requires motor capacity and the SMG’s main parameters, supporting that part of the claim. But the paper does not say it can provide only an average estimate: the Introduction and Conclusions describe evaluation under quasi-balanced and unbalanced conditions, validated against measurements, and the discussion of Riemann summation addresses the mismatch between an assumed average starting current and measured current. (LLM, conf=0.85)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 32

  1. 10.1109/TIA.2012.2209621 · DOI
  2. 10.1109/TIE.2017.2669018 · DOI
  3. 10.1109/TIE.2012.2193863 · DOI
  4. 10.1049/iet-est.2010.0082 · DOI
  5. 10.1109/ESTS.2007.372103 · DOI
  6. 10.1080/15325000490228423 · DOI
  7. 10.1109/ISIEA.2009.5356387 · DOI
  8. 2017, IEEE Recommended Practice for Electrical Installations on Shipboard
  9. 2015, IEC Standard for Testing and Measurement Techniques Power Quality Measurement Methods
  10. 2016, Requirements Concerning Electrical and Electronic Installations
  11. 2016, Guide for Building and Classing Part 4 Vessel Systems and Machinery
  12. 2016, Rules for classification Ships Part 4 Systems and components Chapter 8 Electrical installations
  13. 2016, Rules and Regulation for Classification of Steel Ships
  14. 10.1109/APEC.2018.8341061 · DOI
  15. 10.1109/TEC.2017.2691803 · DOI
  16. 10.1109/IAS.2011.6074427 · DOI
  17. guerrero, 0, Shipboard microgrids: Maritime islanded power systems technologies, Proc Int Exhib Conf Power Electron Intell Motion Renewable Energy Energy Manage, 1
  18. 10.1109/IECON.2010.5675297 · DOI
  19. 10.1109/ESTS.2009.4906549 · DOI
  20. 10.1049/iet-gtd.2015.1572 · DOI
  21. 10.1109/TIE.2010.2066534 · DOI · Paper page
  22. 10.1109/TPWRS.2011.2163948 · DOI
  23. 10.1109/TIA.2016.2601558 · DOI
  24. 10.1007/s40565-015-0108-0 · DOI
  25. 10.1109/TTE.2016.2552720 · DOI
  26. 10.1109/IECON.2017.8216385 · DOI
  27. 10.1109/TPEL.2004.826536 · DOI
  28. 10.1109/TIA.2004.836302 · DOI
  29. 10.1109/TPEL.2007.904243 · DOI
  30. 10.1109/28.556647 · DOI
  31. 10.1109/UPEC.2014.6934738 · DOI
  32. 10.1016/j.epsr.2015.12.032 · DOI

Cited by

Sorted by citations

Metadata

Authors
Liu, W., Tarasiuk, T., Su, C.-L., Gorniak, M., Savaghebi, M., Vasquez, J. C., & Guerrero, J. M.
Affiliations
  • Aalborg University (DK)
  • Gdynia Maritime University (PL)
  • National Kaohsiung University of Science and Technology (TW)
  • University of Southern Denmark (DK)
Venue
IEEE Transactions on Industrial Electronics
Published
2019-10
Volume
66
Issue
10
Pages
7683-7693
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W2795700581
Cited by
17
References
0
Citations by year
2026: 4 · 2025: 1 · 2024: 1 · 2023: 4 · 2021: 3 · 2020: 4
FWCI
0.67
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Industrial Electronics (publishedVersion)
  • VBN Forskningsportal (Aalborg Universitet) (acceptedVersion, other-oa)
  • University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion)
Funders
National Science Centre, Poland (DEC-2012/07/E/ST8/01688)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power Systems and Control
Keywords
voltage sag, shipboard microgrids, voltage unbalance, power quality

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review