The DOI matches its Crossref record.
Resilient Control Design for Load Frequency Control System Under False Data Injection Attacks
Abstract
Smart power grids are being enhanced by adding a communication infrastructure to improve their reliability, sustainability, and efficiency. Despite all of these significant advantages, their open communication architecture and connectivity renders the power systems' vulnerability to a range of cyberattacks. This article proposes a novel resilient control system for load frequency control (LFC) system under false data injection (FDI) attacks. It is common to use encryption in data transfer links as the first layer of defending mechanism; here, we propose a second defense layer that can jointly detect and mitigate FDI attacks on power systems. In this article, we propose a new anomaly detection technique that consists of a Luenberger observer and an artificial neural network (ANN). Since FDI attacks can happen rapidly, the observer structure is enhanced by the extended Kalman filter to improve the ANN ability for online detection and estimation. The resilient controller is designed based on the attack estimation, which can eliminate the need for control reconfiguration. The resiliency of the proposed design against FDI attacks is tested on the LFC system. The simulation results clearly show that the proposed control system can successfully detect anomalies and compensate for their adverse effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ghiasi, M., Niknam, T., Wang, Z., Mehrandezh, M., Dehghani, M., & Ghadimi, N. (2023) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.108975 · Cited by 494
A survey on attack detection, estimation and control of industrial cyber–physical systems
Zhang, D., Wang, Q.-G., Feng, G., Shi, Y., & Vasilakos, A. V. (2021) · ISA Transactions · doi:10.1016/j.isatra.2021.01.036 · Cited by 317
Detection of False Data Injection of PV Production
Riggs, H., Tufail, S., Khan, M., Parvez, I., & Sarwat, A. I. (2021) · 2021 IEEE Green Technologies Conference (GreenTech) · doi:10.1109/greentech48523.2021.00012 · Cited by 23
Self-citationOn The Efficacy of Physics-Informed Context-Based Anomaly Detection for Power Systems
Nafees, M. N., Saxena, N., & Burnap, P. (2022) · 2022 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm) · doi:10.1109/smartgridcomm52983.2022.9961034 · Cited by 4
Metadata
- Authors
- Abbaspour, A., Sargolzaei, A., Forouzannezhad, P., Yen, K. K., & Sarwat, A. I.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2020-09
- Volume
- 67
- Issue
- 9
- Pages
- 7951-7962
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2977733636
- Cited by
- 219
- References
- 0
- FWCI
- 11.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Resilient Control Design for Load Frequency Control System Under False Data Injection Attacks. https://app.cochat.ai/papers/10.1109/tie.2019.2944091
- The paper
- Abbaspour, A., Sargolzaei, A., Forouzannezhad, P., Yen, K. K., & Sarwat, A. I. (2020). Resilient Control Design for Load Frequency Control System Under False Data Injection Attacks. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2019.2944091
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.