A Step-Up Multilevel Inverter Topology Using Novel Switched Capacitor Converters With Reduced Components
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
In this article, basic cell (BC) of a novel switched capacitor converter (SCC) has been proposed first. After that, the generalized structure of proposed SCC is developed. The developed SCC requires reduced number of switches, drivers, diodes, capacitors, and lower number of conducting switches in current flow paths and capacitor charging paths as compared to the other recently developed SCCs. A switched capacitor multilevel inverter (SCMLI) utilizing two numbers of generalized SCCs is developed next. Further, cascaded extension of proposed SCMLI is realized and analyzed for symmetric and asymmetric dc source configurations. A detail analysis of optimum selection of capacitance for switched capacitors of 13-level SCMLI is presented. An extensive comparison study shows that the proposed SCMLI requires lower number of components as compared to other SCMLIs. Further, the proposed structure has minimum cost function per level per boosting factor as compared to the other SCMLIs. Extensive experimental results considering fundamental switching frequency scheme are presented to validate the merits and effectiveness of the proposed structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715 · cited 1×
“become very popular in different industrial applications for generating a specific output voltage level (up-to five levels) [6]–[7].”
BackgroundRecent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“As compared to classic two-level inverters, MLIs have numerous advantages such as they can handle high power level using medium voltage rated semiconductor devices, they can produce output voltage waveform with better harmonic spectrum, they are sustained by lower electromagnetic interfaces and lower dv/dt stresses, a…”
BackgroundPeng, F. Z. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.808920 · Cited by 3,228
Multilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530601 · Cited by 2,665
Multilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.502161 · Cited by 2,604
The age of multilevel converters arrives
Franquelo, L., Rodriguez, J., Leon, J., Kouro, S., Portillo, R., & Prats, M. (2008) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2008.923519 · Cited by 2,016 · cited 1×
“IN RECENT years, multilevel inverters (MLIs) have become a viable dc to ac power conversion system for different applications, such as renewable energy conversion systems, motor drive applications, UPS systems, flexible alternating current transmission system (FACTS) applications, induction heating systems, distribute…”
BackgroundAbu-Rub, H., Holtz, J., Rodriguez, J., & Baoming, G. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2043039 · Cited by 1,337 · cited 1×
“become very popular in different industrial applications for generating a specific output voltage level (up-to five levels) [6]–[7].”
BackgroundMultilevel Inverter Topologies With Reduced Device Count: A Review
Gupta, K. K., Ranjan, A., Bhatnagar, P., Sahu, L. K., & Jain, S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2405012 · Cited by 1,193 · cited 1×
“A number of reduced device count MLIs have been proposed in recent years [8], [9].”
BackgroundA Switched-Capacitor Inverter Using Series/Parallel Conversion With Inductive Load
Hinago, Y., & Koizumi, H. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2158768 · Cited by 535
Hybrid Multilevel Inverter Using Switched Capacitor Units
Babaei, E., & Gowgani, S. S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2290769 · Cited by 498 · cited 10×
“From this figure, it can be observe that the proposed SCC requires lower number of semiconductor devices as compared to the SCCs presented in [16] and [17] for producing a NL_scc.”
BackgroundResultInfluential
Cited by
Switched-Capacitor Multilevel Inverters: A Comprehensive Review
Barzegarkhoo, R., Forouzesh, M., Lee, S. S., Blaabjerg, F., & Siwakoti, Y. P. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164508 · Cited by 265
Metadata
- Authors
- Roy, T., & Sadhu, P. K.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2021-01
- Volume
- 68
- Issue
- 1
- Pages
- 236-247
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2999956206
- Cited by
- 195
- References
- 23
- FWCI
- 10.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.